9. Troubleshooting

9.1 Indoor Unit Error Display

Operation lamp
Timer lamp
☆ 1 time
☆ 2 times
☆ 3 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 7 times
☆ 2 times
☆ 3 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 1 times
☆ 2 times
☆ 3 times
☆ 5 times
O(light)
X(off)
Display LED STATUS
X
E0
Indoor unit EEPROM parameter error
X
E1
Indoor / outdoor units communication error
Zero crossing signal detection error(only for
X
E2
MS12FU-09HRDN1-QRC8W, MS12FU-09HRDN1-QRC8GW,
MS12FU-12HRDN1-QRC8GW, MS12F-24HRDN1-QRC8GW)
X
E3
Indoor fan speed has been out of control
Open circuit or short circuit of indoor room temperature T1
X
E4
sensor
Open circuit or short circuit of evaporator coil temperature
X
E5
T2 sensor
X
EC
Refrigerant Leakage Detection
Open circuit or short circuit of outdoor ambient T4
O
F1
temperature sensor
Open circuit or short circuit of condenser coil temperature
O
F2
T3 sensor
Open circuit or short circuit of compressor discharge T5
O
F3
temperature sensor
O
F4
Outdoor unit EEPROM parameter error
O
F5
Outdoor fan speed has been out of control
P0
IPM malfunction or IGBT over-strong current protection
P1
Over voltage or over low voltage protection
High temperature protection of compressor top diagnosis
and solution(Only for KFU-24HRFN1-QRC8W,
P2
KFU-24HRFN1-QRD0GW and KFU-24HRDN1-QRC8GW
models)
P4
Inverter compressor drive error
☆(flash)