OPERATING HEATER
Continued
4. Press in and turn control knob clockwise
to the OFF position (see Figure 27).
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow "B" in the
safety information, column 1, page 19. If
you don't smell gas, go to the next step.
6. Press in and turn control knob counter-
clockwise
Press in control knob for five (5) seconds
(see Figure 27).
Note: You may be running this heater for
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 21.
8. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
• If control knob does not pop out when
released, contact a qualified service person
or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8.
9. Slightly push in and turn control knob coun-
terclockwise
10. Wait one minute and switch selector switch
to the ON position to light burners. Note:
AUTO is only functional when using
GWMT1 or GWMS2 optional accessories.
11. Set flame adjustment knob to any level
between HI and LO.
Flame Adjustment Knob
Selector Switch in
Ignitor
OFF Position
Button
Figure 27 - Control Knob and Ignitor
Button Location (Shown as Supplied, No
Control Options)
Available from Allparts Equipment and Accessories - 1-877-475-5660 - www.allpartsinc.com
to the PILOT position.
to the ON position.
AUTO
OFF
ON
Control
Knob
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: Make sure the
selector switch is in the OFF
position when you are away from
home for long periods of time.
Heater will come on automati-
cally with selector switch in the
ON position.
Note: The pilot flame on natural gas units will
have a slight curve, but flame should be blue
and have no yellow or orange color.
Pilot Burner
Figure 28 - Pilot (Propane/LP)
Pilot Burner
Figure 29 - Pilot (Natural)
TO TURN GAS OFF
TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
OFF position.
2a. Set selector switch in the OFF position.
2b.
If Using Optional Hand-Held Remote:
lector switch in the OFF position to prevent
draining battery.
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot
lit by doing one of the following:
1. Turn control knob clockwise
PILOT position.
2. Use remote control manual OFF button.
3. Set selector switch in the OFF position.
Ignitor Electrode
Ignitor
Electrode
to the
Set se-