Desa FLAME-MAX Vintage Oak Series Owner's Operation And Installation Manual page 14

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

INSTALLATION
Continued
For propane/LP units, the installer must supply
an external regulator. The external regulator will
reduce incoming gas pressure. You must reduce
incoming gas pressure to between 11" and 14" of
water. If you do not reduce incoming gas pres-
sure, heater regulator damage could occur. Install
external regulator with the vent pointing down
as shown in Figure 15. Pointing the vent down
protects it from freezing rain or sleet.
CAUTION: Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" diameter or greater to allow
proper gas volume to heater. If
pipe is too small, undue loss of
volume will occur.
Installation must include an equipment shutoff
valve, union, and plugged 1/8" NPT tap. Locate
NPT tap within reach for test gauge hook up. NPT
tap must be upstream from heater (see Figure 16
or 17, depending on your model).
IMPORTANT: Install equipment shutoff valve
in an accessible location. The equipment shutoff
valve is for turning on or shutting off the gas to
the appliance.
Check your building codes for any special re-
quirements for locating equipment shutoff valve
to fireplaces.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could result
in clogged heater valves.
WARNING: Use pipe joint
sealant that is resistant to liquid
petroleum (LP) gas.
We recommend that you install a sediment trap in
supply line as shown in Figure 16 or 17, depending
on your model. Locate sediment trap where it is
within reach for cleaning. Install in piping system
between fuel supply and heater. Locate sediment
trap where trapped matter is not likely to freeze.
A sediment trap traps moisture and contaminants.
This keeps them from going into heater controls. If
sediment trap is not installed or is installed wrong,
heater may not run properly.
Available from Allparts Equipment and Accessories - 1-877-475-5660 - www.allpartsinc.com
Propane/LP
Supply Tank
Figure 15 - External Regulator With Vent
Pointing Down
Propane/LP From
External Regulator
(11" W.C.** to 14"
W.C. Pressure)
Natural From Gas
Meter (5" W.C.** to
10.5" W.C.
Pressure)
3" Minimum
Tee Cap Pipe
Joint
Nipple
Sediment Trap
Figure 16 - Gas Connection (Variable
Manually-Controlled Models Only)
CSA Design-
Certified Equipment
Shutoff Valve With
1/8" NPT Tap*
Approved Flexible
Gas Hose (if
allowed by local
codes)
Gas Control
Figure 17 - Gas Connection (Remote-
Ready Models Only)
* Purchase the optional CSA design-certified
equipment shutoff valve from your dealer. See
Accessories, page 34.
** Minimum inlet pressure for purpose of input
adjustment.
External
Regulator
Vent
Pointing
Down
CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*
Approved Flexible
Gas Hose (if allowed
by local codes)
Gas Regulator
Propane/LP From
External Regulator
(11" W.C.** to 14"
W.C. Pressure)
Natural From Gas
Meter (5" W.C.** to
10.5" W.C.
Pressure)
3" Minimum
Pipe Cap Tee
Nipple
Sediment Trap
Joint

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flame-max golden oak seriesVintage 18"Golden 24"

Table of Contents