Download Print this page

Wolf IM15 Installation Manual page 6

Multi-function cooktop
Hide thumbs Also See for IM15:

Advertisement

Multi-Function Cooktop Specifications
Gas Supply Requirements
EXPLOSION HAZARD: Use a certified gas supply line
and install a gas shut-off valve. Securely tighten all gas
connections. Failure to follow these instructions can
result in explosion, fire or death.
IMPORTANT NOTE: This installation must conform with
local codes and ordinances. In the absence of local
codes, installations must conform with American National
Standard, National Fuel Gas Code ANSI Z223.1—latest
edition or CANI—B149.1 or 2.
The gas multi-function cooktop is equipped for use with
natural or LP gas. It is design certified by the Canadian
Standards Association (CSA) for natural or LP gases. The
product rating plate, located on the underside of the
cooktop, has information on the type of gas that should be
used. Refer to the illustration below. If this information
does not agree with the type of gas available, contact your
Wolf dealer or local gas supplier. To obtain local dealer
information, visit the find a showroom section of our
website, wolfappliance.com.
RATING PLATE
Location of rating plate.
SHUT-OFF VALVE
OPEN POSITION
TO APPLIANCE
GAS SUPPLY
Gas shut-off valve.
GAS SUPPLY LINE
IMPORTANT NOTE: The gas multi-function cooktop must
be connected to a regulated gas supply.
3
A gas supply line of
/
" rigid pipe must be provided to the
4
cooktop. For LP gas, piping or tubing size can be
minimum. LP gas suppliers usually determine the size and
materials used on the system. If local codes permit, a
1
3
certified,
/
" or
/
" ID flexible metal appliance connector
2
4
is recommended to connect the cooktop to the gas supply
line. The gas pressure regulator on the cooktop has
female threads.
IMPORTANT NOTE: The supply line must be equipped
with an approved external gas shut-off valve located near
the cooktop in an accessible location. Do not block
access to the shut-off valve. Refer to the illustration below.
The Wolf natural gas multi-function cooktop will function
up to an altitude of 10,250' (3124 m) without any adjust-
ment. LP gas cooktops will function up to 8,600' (2621 m)
without adjustment. If the installation exceeds these eleva-
tions, contact your authorized Wolf dealer for a high
altitude conversion kit.
Before connecting the gas supply, make sure all valves
are in a closed position. Do not connect the gas supply
to an appliance that shows any sign of damage.