Self-Diagnosis Function; Self-Diagnosis Display; Service Mode Display; Display Method - Sony GV-D300 Service Manual

Table of Contents

Advertisement

1.

SELF-DIAGNOSIS FUNCTION

When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the LCD screen or monitor
TV (Note) what to do. This function consists of two display; self-
diagnosis display and service mode display.
Details of the self-diagnosis functions are provided in the Instruction
manual.
LCD screen or monitor TV
C : 3 1 : 1 1
Repaired by:
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
3.

SERVICE MODE DISPLAY

The service mode display shows up to six self-diagnosis codes shown in the past.
3-1.

Display Method

While pressing the "STOP" key, set the switch from OFF to ON, and continue pressing the "STOP" key for 10 seconds continuously. The
service mode will be displayed, and the counter will show the backup No. and the 5-character self-diagnosis codes.
LCD screen or monitor TV
[3] C : 3 1 : 1 1
Backup No.
Order of previous errors
3-2.

Switching of Backup No.

By rotating the control dial, past self-diagnosis codes will be shown in order. The backup No. in the [] indicates the order in which the
problem occurred. (If the number of problems which occurred is less than 6, only the number of problems which occurred will be shown.)
[1] : Occurred first time
[2] : Occurred second time
[3] : Occurred third time
3-3.

End of Display

Turning OFF the power supply will end the service mode display.
Note: The "self-diagnosis display" data will be backed up by the coin-type lithium battery of FP-571 flexible board. When this coin-type lithium battery
is removed, the "self-diagnosis display" data will be lost by initialization.
SELF-DIAGNOSIS FUNCTION
Blinks at 3.2Hz
1 1
C
3 1
Block
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Lights up
[3]
C : 3 1 : 1 1
self-diagnosis codes
[4] : Occurred fourth time
[5] : Occurred fifth time
[6] : Occurred the last time
2.

SELF-DIAGNOSIS DISPLAY

When problems occur while the unit is operating, the counter of the
viewfinder shows a 4-digit display consisting of an alphabet and
numbers, which blinks at 3.2 Hz. This 5-character display indicates
the "repaired by:", "block" in which the problem occurred, and
"detailed code" of the problem.
Note: Set the DISPLAY in the menu system to V-OUT/LCD only for the
model with LCD screen, and press the DISPLAY button.
Detailed Code
Refer to page 7.
Self-diagnosis Code Table.
— 6 —
Control dial

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gv-d900eGv-d300eGv-d900

Table of Contents