Maintenance - Toshiba RAV-SM567CTP-E Owner's Manual

Air conditioner (split type)
Hide thumbs Also See for RAV-SM567CTP-E:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
3
Push TIME
buttons, to adjust the power saving mode setting.
• Each push of the button changes the power level by 1 % within the range from 100 % to 50 %.
• The factory default is 75 %.
4
Push
button.
5
Push
button to complete the setting.
NOTE
• During a Power save operation, the maximum current of the outdoor unit is limited. The operating power consumption
might not be lowered, however, under certain conditions.
• Capability of the air conditioner is saved during the Power save operation. The room may not become cool or warm
enough.
• A Power save operation cannot be programmed with the central control remote controller and depending on the
installation conditions of the outdoor unit.
• If multiple units are connected as a group, all of them are put in Power save mode.
• The Power save feature might be restricted, depending on the outdoor unit used. For details, contact the original
retailer.
67-EN
Setting of power level in
power saving mode
8

Maintenance

WARNING
• Cleaning the air filter and other parts of the air filter involves dangerous work in high places. Ask a qualified
installer or qualified service person to do it. Do not attempt it by yourself.
Cleaning air filters
Clogged air filters will reduce the cooling and heating performance.
(1) If "
" is displayed on the remote controller, clean the air filters.
(2) When the cleaning of air filters has been completed, push
"
" disappears.
◆ When the unit will not be used for a long time
1. Perform the fan operation for a couple of hours to dry inside.
2. Push
on the remote controller to stop running, and turn off the circuit breaker.
3. Clean the air filters and reinstall them.
◆ Before the cooling season
Clean the drain pan.
Contact the dealer where you purchased the product.
(Drain does not work if the drain pan or vent is clogged. In some cases the drain may overflow and wet the wall or
floor. Clean the drain pan before the cooling season.)
– 34 –
(1)
button.
(2)
68-EN

Advertisement

Table of Contents
loading

Table of Contents