Specifications
2.1.2 Heat Pump
Model
Cooling Capacity
Heating Capacity
Casing
Body
Dimensions (W*H*D)
Front Panel
Rows x Columns x FPI
Coil
Face Area
Type
Motor Output
Running Current
Fan
Air Flow Rate(H/M/L)
Drive
Speed control
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side
Pipe Connections Gas Side
Drain Pipe(OD)
Net Weight
Noise Level(Sound Press, 1.5m, H/M/L)
Power Supply
Refrigerant Control
Power cable
Transmission cable
Panel Color
Stuffing Quantity Without S/parts
Notes:-
1. Capacities are based on the following conditions:
Cooling
• Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
Heating
• Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. L.E.V.:Linear Expansion Valve
24
Indoor Unit
LRNN076TCA(C)0
Unit
2,100
W
kcal/h
1,806
7,165
Btu/h
W
2,363
2,031
kcal/h
8,061
Btu/h
Galvanized Steel Plate
860*390*180
mm
inch
33.8*15.3*7.0
1050*480*30
mm
41.3*18.9*1.2
inch
2*12*18
0.17
m
2
Cross Flow Fan
14
W
A
0.22
6/5/4
cmm
212/177/141
cfm
Direct
Phase Control
Mi c roprocessor, Thermostat for cool i n g and heati n g Mi c roprocessor, Thermostat for cool i n g and heati n g Mi c roprocessor, Thermostat for cool i n g and heati n g
Foamed polystrene
Fuse, Thermal Fuse for Fan Motor
Ø6.35(1/4)
mm(inch)
Ø12.7(1/2)
mm(inch)
32.0
mm
17(37.5)
kg(lbs)
dBA±3
35/32/29
1 / 220 ~ 240 / 50Hz
Ø / V / Hz
LEV
CV2.0 X 3C
mm
2
CVV-SB 1.25 X 2C
mm
2
White
263/539
20/40ft
Heat Pump (50Hz)
LRNN096TCA(C)0
LRNN126TCA(C)0
2,600
2,235
8,871
2,925
2,515
9,980
Galvanized Steel Plate
Galvanized Steel Plate
860*390*180
33.8*15.3*7.0
1050*480*30
41.3*18.9*1.2
2*12*21
0.17
Cross Flow Fan
14
0.22
7/6/5
247/212/177
Direct
Phase Control
Foamed polystrene
Foamed polystrene
Fuse, Thermal Fuse for Fan Motor
Fuse, Thermal Fuse for Fan Motor
Ø6.35(1/4)
Ø12.7(1/2)
32.0
17(37.5)
37/34/31
1 / 220 ~ 240 / 50Hz
1 / 220 ~ 240 / 50Hz
LEV
CV2.0 X 3C
CVV-SB 1.25 X 2C
CVV-SB 1.25 X 2C
White
263/539
Conversion Formula
Kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3,500
3,009
11,942
3,938
3,385
13,435
860*390*180
33.8*15.3*7.0
1050*480*30
41.3*18.9*1.2
2*12*21
0.17
Cross Flow Fan
14
0.22
10/9/8
353/318/283
Direct
Phase Control
Ø6.35(1/4)
Ø12.7(1/2)
32.0
17(37.5)
39/36/35
LEV
CV2.0 X 3C
White
263/539
3
/min x 35.3