Horizontal Installations; Startup Procedure & Adjustment; Heat Anticipator Setting; Drain Trap Priming - Goodman GMS95 Installation Instructions Manual

Goodman gms95 gas-fired warm air furnace
Table of Contents

Advertisement

AIR FLOW
CENTRAL
RETURN
GRILLE
SIDE RETURN
EXTERNAL FILTER
RACK KIT
(EITHER SIDE)
Possible Upright Upflow
Filter Locations
NOTE: Internal filter retention is not provided on this furnace. If an
internal installation is desired, an internal filter retention kit is avail-
able as an accessory. Please see your distributor for details.
H
I
ORIZONTAL
NSTALLATIONS
Filters must be installed in either the central return register or in the
return air duct work.
XIV. ST
XIV
XIV
XIV
XIV
. ST
. ST
. STAR
. ST
AR
ARTUP PR
AR
AR
TUP PROCEDURE & AD
TUP PR
TUP PR
TUP PR
Furnace must have a 115 VAC power supply properly connected
and grounded. Proper polarity must be maintained for correct op-
eration. In addition to the following start-up and adjustment items,
refer to further information in Section XVI, Operational Checks.
H
A
S
EAT
NTICIPATOR
ETTING
The heat anticipator in the room thermostat must be correctly ad-
justed to obtain the proper number of cycles per hour and to pre-
vent "overshooting" of the setting. Set the heat anticipator setting to
0.7 amps. Follow the thermostat manufacturer's instructions on
how to adjust the heat anticipator setting.
D
T
P
RAIN
RAP
RIMING
The drain trap must be primed prior to furnace startup. To prime, fill
the drain trap with water. This ensures proper furnace drainage
upon startup and prohibits the possibility of flue gases escaping
through the drain system.
F
URNACE OPERATION
Purge gas lines of air prior to startup. Be sure not purge lines into
an enclosed burner compartment.
Check for leaks using an approved chloride-free soap and water
solution, an electronic combustible gas detector, or other approved
method. Verify that all required kits (propane gas, high altitude,
etc.) have been appropriately installed.
F
S
URNACE
TARTUP
1. Close the manual gas shutoff valve external to the furnace.
2. Turn off the electrical power to the furnace.
3. Set the room thermostat to the lowest possible setting.
4. Remove the burner compartment door.
NOTE: This furnace is equipped with an ignition device which
automatically lights the burner. Do not try to light the burner by
hand.
5. Move the furnace gas valve manual control to the OFF
position.
FILTER
ACCESS
DOOR
RETURN
DUCT
FILTER
SUPPORT
BRACKET
(PROVIDED)
AIR FLOW
Possible Upright Counterflow
OCEDURE & AD
OCEDURE & AD
OCEDURE & AD
OCEDURE & ADJUST
JUST
JUST
JUSTMENT
JUST
MENT
MENT
MENT
MENT
6. Wait five minutes then smell for gas. Be sure to check near
the floor as some types of gas are heavier than air.
7. If you smell gas after five minutes, immediately follow the
instructions on page 4 of this manual. If you do not smell
gas after five minutes, move the furnace gas valve manual
control to the ON position.
CENTRAL
RETURN
8. Replace the burner compartment door.
GRILLE
9. Open the manual gas shutoff valve external to the furnace.
10. Turn on the electrical power to the furnace.
11. Adjust the thermostat to a setting above room temperature.
12. After the burners are lit, set the thermostat to desired
temperature.
F
S
URNACE
HUTDOWN
1. Set the thermostat to the lowest setting. The integrated
control will close the gas valve and extinguish flame.
Following a 15 second delay, the induced draft blower will
be de-energized. After a 90, 120, 150 or 180 second delay
period (field selectable), the circulator blower will be de-
energized.
2. Remove the burner compartment door and move the furnace
gas valve manual control to the OFF position.
3. Close the manual gas shutoff valve external to the furnace.
4. Replace the burner compartment door.
G
S
AS
UPPLY
T
O PREVENT UNRELIABLE OPERATION OR EQUIPMENT DAMAGE, THE INLET
GAS SUPPLY PRESSURE MUST BE AS SPECIFIED ON THE UNIT RATING PLATE
WITH ALL OTHER HOUSEHOLD GAS FIRED APPLIANCES OPERATING.
W
-R
HITE
ODGERS
The line pressure supplied to the gas valve must be within the
range specified below.
Natural Gas
Propane Gas
The supply pressure can be measured at the gas valve inlet pres-
sure tap or at a hose fitting installed in the gas piping drip leg. The
supply pressure must be measured with the burners operating.
To measure the gas supply pressure, use the following procedure.
Gas Valve
On/Off
Selector
Switch
INLET
Inlet Pressure Tap
1. Turn OFF gas to furnace at the manual gas shutoff valve
external to the furnace.
2. Connect a calibrated water manometer (or appropriate gas
pressure gauge) at either the gas valve inlet pressure tap
or the gas piping drip leg.
27
P
M
RESSURE
EASUREMENT
CAUTION
36F22 G
V
AS
ALVE
Inlet Gas Supply Pressure
Minimum:5.0" W.C. Maximum :10.0" W.C.
Minimum:11.0" W.C. Maximum :13.0" W.C.
Pressure Regulator
(Side of Valve)
Adjustment
(Under Cap Screw)
White-Rodgers Model 36F22
OUTLET
Outlet (Manifold)
Pressure Tap