Mechanical Adjustment; The Number And Position Of Test Point; Ace Head Position (X-Point) Adjustment - Sony SLV-D100 Service Manual

Sony slv-d100 dvd player/ video cassette recorder
Hide thumbs Also See for SLV-D100:
Table of Contents

Advertisement

QQ
3 7 63 1515 0

6-2 Mechanical Adjustment

Note : Refer to the Mechanical Manual "TS-10 (P/N: 9-921-790-11) for the adjustment and confirmation of ass'y full deck.

6-2-1 The Number and Position of Test Point

Test point :
TP2 (Audio Output)
TP3 (Envelope)
TP4 (H'D S/W-Trigger)
TP5 (Control Pulse)
TE
L 13942296513

6-2-2 ACE Head Position (X-Point) Adjustment

(See the 2-2-1(d) ACE Head Position (X-Point) Adjustment on
2-2 of the Mechanical Manual)
1) Playback the alignment tape (Color bar).
www
2) Momently short-cricuit the test point on F/Timer PCB with
pincers to set the adjustment mode.
(See Fig. 6-2)
.
3) Press the "5" button of remote control then adjustment is op-
erated automatically. (See Fig. 6-1)
http://www.xiaoyu163.com
CONTROL PULSE
HEAD SWITCHING
AUDIO OUTPUT
Fig. 6-3 Location of Test point (VCR Main PCB-Top View)
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
Q Q
3
6 7
1 3
1 5
ENVELOPE
4) Connect the CH-1 probe to TP3 (Envelope) the CH-2
probe to TP4 (H'D switching pulse) and then trigger to
CH-1.
5) Insert the (-) driver into the X-Point adjustment hole
and adjust it so that envelope waveform is maximum.
6) Turn the Power off.
co
.
6-3
9 4
2 8
0 5
8
2 9
9 4
2 8
m
9 9
9 9