Electrolux EIGD55H Technical & Service Manual page 57

Wave-touch & iq-touch front-load dryer
Hide thumbs Also See for EIGD55H:
Table of Contents

Advertisement

E E r r r r o o r r
F F a a u u l l t t
C C o o d d e e
E31
Contact Sensor
frequency too high.
E32
Contact Sensor
frequency too low.
E42
Door Sensing
failure.
E51
Motor Relay failure
E52
Motor Fault –
motor stopped or
not starting.
E53
Motor Centripetal
Switch Failure
E54
Motor Sensing
failure
E61
Heater Relay failure.
E63
Heater to Earth
Ground
E64
Heater Open
Circuit
E65
High Limit
Thermostat trip
count too high
E66
Thermal Limiter
Open Circuit
Heaters Sensing
E67
Failure
Outlet Control
E71
Thermistor open
circuit
P P o o s s s s i i b b l l e e F F a a u u l l t t C C o o n n d d i i t t i i o o n n s s
Electronic Control Board
defective or foreign object
interfering with contact sensor.
Electronic Control Board
defective or foreign object
interfering with contact sensor.
Electronic Control Board
defective.
Motor Relay stuck open or
closed; Wiring defective.
Motor overheating; Laundry
load too heavy; Low power
supply; Motor, or Wiring
defective.
Motor Centripetal Switch,
Electronic Control Board
Defective, or wiring defective.
Electronic Control Board
defective
Heater relay stuck open or
closed; Wiring defective.
Heating element or wiring
defective
Heating element or wiring
defective.
High vent restriction, High
Limit Thermostat defective or
Inlet Thermal Limiter tripped
(Electric Model only)
Outlet Thermal Limiter tripped
Inlet Thermal Limiter tripped
(Gas Model only) or wiring
defective.
Electronic Control Board
defective.
Outlet Control Thermistor or
wiring defective
E E l l e e c c t t r r o o n n i i c c C C o o n n t t r r o o l l
P P o o s s s s i i b b l l e e S S o o l l u u t t i i o o n n s s
Check Contact Sensor and wiring. If no problems are found
with Contact Sensor, replace Electronic Control Board.
Check Contact Sensor and wiring. If no problems are found
with Contact Sensor, replace Electronic Control Board.
Replace Electronic Control Board.
If motor runs continuously with power applied check for short
circuit across motor relay (RL2), or L1 applied to motor relay
output (J3-1) with cycle stopped. If motor does not start
when "start" key is pressed, check for open circuit between
L1 and motor relay connection (J3-2). If no wiring problems
found, replace Electronic Control Board.
Remove any load from dryer and check if drum turns freely
by hand. Check L1 power supply voltage, motor wiring, and
motor thermal protector (if motor thermal protector has
tripped, it may take up to 30 minutes to reset).
Check wiring. Check if Motor Centripetal Switches are stuck
in open or closed positions. Replace motor. Replace
Electronic Control Board.
Replace Electronic Control Board and retest.
Check for short circuit across heater relay(s) (RL5, RL6, RL7)
or L1 applied to heater relay output(s) (J5-2, J7-1, J7-3) with
cycle stopped. Check for open circuit between L1 and heater
relay connection(s) (J5-1, J5-3, J7-2). If no wiring problems
are found, replace Electronic Control Board and retest.
Check heater coils and connections for short circuits to the
cabinet. Replace heater and/or wiring and retest.
Check heater coils and connections for open circuits.
Replace heater and/or wiring and retest.
For Electric Model, check Inlet Thermal Limiter for continuity.
If Thermal Limiter is open, check for evidence of high temper-
ature event and any resulting damage. If no further damage is
evident, replace Thermal Limiter. If no problems are found
with Thermal Limiter, check exhaust vent system for air
blockages. If no problems with vent restrictions,
check/replace High Limit Thermostat, and retest.
Check Outlet Thermal Limiter for continuity. For Gas Model,
also check Inlet Thermal Limiter for continuity. If Thermal
Limiter is open, check for evidence of high temperature event
and any resulting damage. If no further damage is evident,
replace Thermal Limiter and retest.
Replace Electronic Control Board and retest.
Check resistance of Outlet Control Thermistor, and check
wiring for open circuit. Resistance should be between 4.9K
Ohm and 6.2K Ohm at room temperature (68-77° F or 20-25°
C). Replace Outlet Control Thermistor and/or wiring and
retest.
3-21