LG GD1329CGS Service Manual page 33

Lg gd1329cgs; gd1329ces; gd1329cgu; gd1329ceu; gd1329cgd; gd1329ced; gd1329qgs; gd1329qes; gd1329qgu; gd1329qeu; gd1329qgd; gd1329qed electric & gas dryer
Hide thumbs Also See for GD1329CGS:
Table of Contents

Advertisement

ONNE TING ELE TRI DRYERS
WARNING:
!
• Connect the power co r d to the terminal block. Each colo r ed wi r e should be connected to
same color sc r e w . Wi r e color indicated on manual is connected to the same color sc r ew
in block. Failu r e to follow these instructions may r esult in a short or overload.
• G r ounding th r ough the neutral conductor is p r ohibited for: (1) new branch-ci r cuit
installations, (2) mobile homes, (3) r ec r eational vehicles, and (4) a r eas whe r e local
codes p r ohibit g r ounding th r ough the neutral conducto r .
hree-Wire Connection for Electric Dryers: Power Cord
• A 3-wire connection is NOT permitted on new
construction after January 1, 1996.
• A UL-listed strain relief is required.
1
Remove the terminal block access cover
on the upper back of the dryer. Install a
UL-listed strain relief into the power cord
through-hole; then thread a UL-listed, 30A,
240V, 3-wire, #10 AWG-minimum copper
conductor power cord through the strain
relief.
Terminal
Block
UL-Listed
Strain Relief
UL-Listed
3-Wire
Power Cord
32
(cont.)
• Use a 30-amp, 240V, UL-listed power cord
with #10 AWG-minimum copper conductor
and closed loop or forked terminals with
upturned ends.
Ground Screw
Ground Wire
2
Attach the two hot leads of the power cord
to the outer terminal block screws. Attach
the neutral wire to the center terminal block
screw. Connect the external ground (if
required by local codes) to the green ground
screw. TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal block access cover.
Neutral
Hot
Hot
(White)
(Red)
(Black)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents