ENERGY TOP W 80 - W 125
4.4 Technical data table
The column on the right gives the abbreviation used on the dataplate.
Data
Model
Max. heating capacity
Min. heating capacity
Max. Heat Output in heating (80/60 °C)
Min. Heat Output in heating (80/60 °C)
Max. Heat Output in heating (50/30 °C)
Min. Heat Output in heating (50/30 °C)
Efficiency Pmax (80/60 °C)
Efficiency Pmin (80/60 °C)
Efficiency Pmax (50/30 °C)
Efficiency Pmin(50/30 °C)
Efficiency 30%
Gas diaphragm (G20)
Gas supply pressure G20
CO
max. (G20)
2
CO
min. (G20)
2
Max. gas delivery G20
Min. gas delivery G20
Gas diaphragm (G31)
Gas supply pressure G31
CO
max. (G31)
2
CO
min. (G31)
2
Max. gas delivery G31
Min. gas delivery G31
Efficiency class Directive 92/42 EEC
NOx emission class
Max. fume temperature (80 °C - 60 °C)
Min. fume temperature (80 °C - 60 °C)
Max. fume temperature (50 °C - 30 °C)
Min. fume temperature (50 °C - 30 °C)
Max. fume flowrate
Min. fume flowrate
Max. working pressure in heating
Min. working pressure in heating
Max. heating temperature
Heating water content
Protection rating
Power supply voltage
Electrical absorption
Empty weight
Type of unit
PIN CE
EN
Unit
ENERGY TOP W 80
kW
kW
kW
kW
kW
kW
%
%
%
%
%
Ø
mbar
%
%
3
m
/h
3
m
/h
Ø
mbar
%
%
kg/h
kg/h
-
-
°C
°C
°C
°C
kg/h
kg/h
bar
bar
°C
litres
IP
V/Hz
W
kg
C
13
cod. 3540I160 - 05/2008 (Rev. 00)
Value
Value
ENERGY TOP W 125
75
116
17
25
73.5
113.7
16.7
24.6
79.5
123
18.3
26.9
98
98
98.5
98.5
106
106
107.5
107.5
109
109
8.50
9.4
20
20
9
9
8.5
8.5
7.94
12.38
1.8
2.65
5.8
7.0
37
37
10
10
9.2
9.2
5.87
9.08
1.33
1.96
5
5
65
65
60
60
43
45
33
34
127.5
197
31.4
44.7
6
6
0.8
0.8
95
95
5
7
X5D
X5D
230V/50Hz
230V/50Hz
95
200
46
51
- C
- C
- C
- C
- C
- C
- B
23
33
43
53
63
83
0461BS0879
(Q)
(Q)
(P)
(P)
(P)
(P)
(NOx)
(PMS)
(tmax)
- B
23
33
29