If the Remote Timer Control (optional) is connected to the boiler, the above adjustments are managed accord-
A
ing to that given in table 1.
Table. 1
Heating temperature adjustment
DHW temperature adjustment (with optional hot
water tank installed)
Summer/Winter changeover
Eco/Comfort selection (with optional hot water tank
installed)
Sliding Temperature
Water system pressure adjustment
The filling pressure with the system cold must be approx. 1.0 bar. If the system pressure falls to values below minimum,
the boiler card will activate fault F37 (fig. 14).
Once the system pressure is restored, the boiler will activate the 120-second air venting cycle indicated on the
A
display by FH.
10
10
9
8
7
6
5
4
3
2
1
0
-10
-20
fig. 13 - Example of parallel compensation curve shift
Adjustment can be made from the Remote Timer Control menu and the boiler
control panel.
Adjustment can be made from the Remote Timer Control menu and the boiler
control panel.
Summer mode has priority over a possible Remote Timer Control heating
demand.
On disabling DHW from the Remote Timer Control menu, the boiler selects
the Economy mode. In this condition, the button
the boiler panel is disabled.
On enabling DHW from the Remote Timer Control menu, the boiler selects
the Comfort mode. In this condition it is possible select one of the two modes
with the button
Both the Remote Timer Control and the boiler card manage Sliding Tempera-
ture adjustment: of the two, the Sliding Temperature of the boiler card has pri-
ority.
fig. 14 - System low pressure fault
cod. 3540I160 - 05/2008 (Rev. 00)
ENERGY TOP W 80 - W 125
OFFSET = 40
90
10
85
80
70
60
50
40
30
20
20
10
(detail 7 - fig. 1).
eco
reset
comfort
9
8
7
6
5
4
3
2
1
0
-10
-20
(detail 7 - fig. 1) on
EN