Weld Output Receptacles And Selecting Cable Sizes - Miller Invision 352 MPa Auto-Line CE Owner's Manual

Hide thumbs Also See for Invision 352 MPa Auto-Line CE:
Table of Contents

Advertisement

5-5. Weld Output Receptacles And Selecting Cable Sizes

NOTICE − The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is
100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine cable
size.
Weld Output
Terminals
!
Turn off power be-
fore connecting to
weld output termi-
nals.
!
Do not use worn,
damaged,
under-
sized,
or
poorly
spliced cables.
+
Output Receptacles
This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
*
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
2
( ) = mm
for metric use
***For distances longer than those shown in this guide, call a factory applications rep. at 920-735-4505 (Miller) or 1-800-332-3281 (Hobart).
OM-245 171 Page 18
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
100 ft (30 m) or Less
10 − 60%
60 − 100%
Duty
Welding
Cycle
Cycle
Amperes
AWG
AWG (mm
2
(mm
)
100
4 (20)
150
3 (30)
200
3 (30)
250
2 (35)
300
1 (50)
1/0 (60)
350
1/0 (60)
2/0 (70)
400
1/0 (60)
2/0 (70)
500
2/0 (70)
3/0 (95)
600
3/0 (95)
4/0 (120)
Not Exceeding***
150 ft
200 ft
(45 m)
(60 m)
Duty
2
)
4 (20)
4 (20)
3 (30)
3 (30)
2 (35)
1 (50)
2 (35)
1 (50)
1/0 (60)
1 (50)
1/0 (60)
2/0 (70)
2/0 (70)
3/0 (95)
3/0 (95)
4/0 (120)
3/0 (95)
4/0 (120)
2x2/0
4/0 (120)
(2x70)
2x2/0
2x3/0
(2x70)
(2x95)
250 ft
300 ft
350 ft
(70 m)
(90 m)
(105 m)
10 − 100% Duty Cycle
2
AWG (mm
)
2 (35)
1 (50)
1/0 (60)
1/0 (60)
2/0 (70)
3/0 (95)
2/0 (70)
3/0 (95)
4/0 (120) 4/0 (120)
2x2/0
3/0 (95)
4/0 (120)
(2x70)
2x2/0
2x3/0
4/0 (120)
(2x70)
(2x95)
2x2/0
2x3/0
2x3/0
(2x70)
(2x95)
(2x95)
2x2/0
2x3/0
2x4/0
(2x70)
(2x95)
(2x120)
2x3/0
2x4/0
3x3/0
(2x95)
(2x120)
(3x95)
2x4/0
3x3/0
3x4/0
(2x120)
(3x95)
(3x120)
Ref. S-0007-J 2011−07
400 ft
(120 m)
1/0 (60)
3/0 (95)
2x2/0
(2x70)
2x3/0
(2x95)
2x4/0
(2x120)
2x4/0
(2x120)
3x3/0
(3x95)
3x4/0
(3x120)

Hide quick links: