Note: The POST error log is automatically cleared with each system restart.

POST error codes

The following table describes the POST error codes and suggested actions to
correct the detected problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 7, "Parts listing, ThinkServer RD220 Type 3729, 3779, 3797, and 3798," on page 231 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
062
Three consecutive boot failures using the
default configuration.
101, 102
System and processor error.
106
System and processor error.
151
Real-time clock error.
32
ThinkServer RD220 Types 3729, 3779, 3797, and 3798: Hardware Maintenance Manual
Event/Error Log. When any log entry is displayed, press Enter (Clear xxxx
log is highlighted on each entry page, where xxxx is the name of the log that
you are viewing).
Action
1. Run the Server Configuration and Boot
Management program, save the configuration,
and restart the server.
2. Update the system firmware to the latest level.
(see the information in Installation and User
Guide).
3. Reseat the following components, one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only)
Microprocessor
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only)
Microprocessor
c. (Trained service technician only) System
board
(Trained service technician only) Replace the system
board.
(Trained service technician only) Replace the system
board.
1. Reseat the battery.
2. Clear CMOS memory. See "System-board
switches and jumpers" on page 152 for
information about how to clear CMOS memory.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) System
board