Lenovo THINKSERVER 3797 Hardware Maintenance Manual page 147

Lenovo computer hardware user manual
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 7, "Parts listing, ThinkServer RD220 Type 3729, 3779, 3797, and 3798," on page 231 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
System event/error log message
+1.8v critical over voltage fault
+1.8v critical under voltage fault
The system real time clock battery is no longer
reliable.
+3.3v critical over voltage fault
+3.3v critical under voltage fault
3.3V Bus Fault
Power Good Fault
VRM 1 Power Good Fault
VRM 2 Power Good Fault
VRM 2 is present
VRM 2 is not present
Memory Area non-critical over temperature
warning
Action
Information only
Information only
Replace the battery.
1. Remove all PCI adapters.
2. Reinstall each PCI adapter, one at a time, restarting the server
each time, to isolate a defective adapter. Replace any defective
adapter.
3. If the error continues, (trained service technician only) replace
the system board.
1. Remove all PCI adapters.
2. Reinstall each PCI adapter, one at a time, restarting the server
each time, to isolate a defective adapter. Replace any defective
adapter.
3. If the error continues, (trained service technician only) replace
the system board.
1. Remove all PCI adapters.
2. Reinstall each PCI adapter, one at a time, restarting the server
each time, to isolate a defective adapter. Replace any defective
adapter.
3. If the error continues, (trained service technician only) replace
the system board.
1. Reseat the power supplies.
2. If the error continues, replace the power backplane.
1. (Trained service technician only) Reseat microprocessor 1.
2. (Trained service technician only) Replace microprocessor 1.
3. (Trained service technician only) Replace the system board.
1. (Trained service technician only) Reseat microprocessor 2.
2. (Trained service technician only) Replace microprocessor 2.
3. (Trained service technician only) Replace the system board.
Information only
If microprocessor 2 is installed, (trained service technician only)
replace the system board.
1. Make sure that the fans are operating and are not obstructed.
2. Make sure that the air baffles are in place and correctly
installed.
3. Make sure that the server cover is installed and fully closed.
139