Horizon Fitness Galaxy Installation And Operation Manual
Horizon Fitness Galaxy Installation And Operation Manual

Horizon Fitness Galaxy Installation And Operation Manual

Horizon galaxy dehumidifier

Advertisement

Quick Links

H
o
r
i
z
H
o
r
i
z
Air Cleaning Equipment, Inc.
303 N. Main St.
Broadway, NC 27505
www.horizondehumidifiers.com
R
e
a
d
a
n
d
S
a
R
e
a
d
a
n
d
S
a
®
®
o
n
G
a
l
a
x
y
-
I
n
o
n
G
a
l
a
x
y
-
I
n
v
e
T
h
e
s
e
I
n
s
t
r
u
c
v
e
T
h
e
s
e
I
n
s
t
r
u
c
s
t
a
l
l
a
t
i
o
n
a
n
d
O
s
t
a
l
l
a
t
i
o
n
a
n
d
O
1
t
i
o
n
s
t
i
o
n
s
p
e
r
a
t
i
o
n
s
M
a
n
p
e
r
a
t
i
o
n
s
M
a
n
u
a
l
u
a
l

Advertisement

Table of Contents
loading

Summary of Contents for Horizon Fitness Galaxy

  • Page 1 ® ® Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC 27505 www.horizondehumidifiers.com...
  • Page 2: Safety Notes

    Safety Notes: • The Horizon Series Dehumidifier must always be connected using the grounded electrical connection as required for all electrical appliances. The warranty is voided and all responsibility for the operation is born by the owner if non-grounded wiring is utilized. •...
  • Page 3: Customer Service

    Identification: For future reference, write down the model, serial number, date of purchase so you can identify your unit when seeking assistance Model Number Horizon Galaxy Serial Number _____________________________ Date of Purchase _____________________________ NOTE: Data label has key operational characteristics of this specific unit.
  • Page 4: Installation

    Installation: The area to be controlled should be sealed with a vapor barrier. If unit is installed in a crawlspace, all vents should be sealed. WARNING : It is recommended to remove dehumidifier from area if applying a liquid vapor barrier. Some coatings dry via “solvent evaporation,” which can be harmful to certain components in your dehumidifier.
  • Page 5: Key Functions

     Support the PVC tubing so that it maintains a smooth downward flow to drain.  Test drain before leaving. Drain Tube – 8’ Long. 10 mm OD. 3) Plug unit into 15 amp grounded outlet. Key functions 1. Power Key indicator light must be on indicated unit is plugged in and has power to it.
  • Page 6 2. Increase Humidity button Press this button to set indoor humidity , according to this sequence: 60%, 65%, 70%, 80%. When the indoor humidity is lower than the set humidity, the machine will stop automatically. When indoor humidity is higher than setpoint, the unit will operate. 3.
  • Page 7: Indicator Lights

    Indicator Lights Led humidity display This led indicator shows two functions 1. When the power supply is on, the Led indicator shows indoor humidity 2. When you set humidity, the Led indicator shows the set humidity Power Indicator Light This indicates the unit has been plugged in and is ready to operate. Please make sure this light is “off”...
  • Page 8 Horizon Galaxy – Front View Unit Cover Control panel Discharge End Cap Power cord Outlet Grille...
  • Page 9 Horizon Galaxy – Back View Unit Cover Handle Power Cord Inlet End Air Inlet Grille Drain Hose Quick Connect Fitting...
  • Page 10: Start The Machine

    DO NOT unplug the power cord directly to force the machine stop working directly. 3. Water Drainage During normal operation, the Galaxy will automatically drain by the force of gravity. If you want to move or store the machine, wait at least 10 minutes to allow the machine to completely defrost and then lean machine gently towards drain to insure the unit is completely drained.
  • Page 11: Maintenance

    Maintenance WARNING – ALWAYS UNPLUG THE UNIT PRIOR TO DOING ANY SERVICE WORK Cleaning the machine body Use soft damp cloth to clean exterior of unit. No solvents should be used. Cleaning the Filter 1. Unplug the unit. 2. Disassemble the filter mesh At the Inlet End of Unit, spin to remove the filter mesh in counter- clockwise...
  • Page 12: Dehumidifier Storage

    4. Reinstall the filter mesh: Filter mesh insert at the back of machine, rotate in clockwise direction Insert the filter mesh into the machine gradually Dehumidifier storage If the unit will be stored for an extended period of time: 1. Turn unit off and allow to dry. 2.
  • Page 13 For optional supply ducting, a separate supply duct adapter is included. 1. Supply Duct Adapter To install, line adapter up with holes on side of unit and push up from base of adapter. If necessary to remove, from bottom of adapter, use the thumb to press the outer side plate to inside, outer four fingers pull from outside, lift the hooks out of cover...
  • Page 14: Troubleshooting

    Troubleshooting Symptom Cause Solution Insure Plug Fully Inserted in Power Cord Connection Outlet Machine Won’t Units Outside Operating Room temperature Over Temperature Range,Manual 105 degree F or Below 33 restart of machine after room Degree F returns to design conditions Clean the filter mesh according Air Filter Clogged to instructions in manual...
  • Page 15: Warranty

    Warranty Seller warrants the equipment to be free from defects in workmanship and materials for a period of 12 months after shipment (60 months/5 years on compressor, evaporator and condenser). This warranty is limited, however, to the repair or replacement of defective equipment.