Lennox Hearth Products Montage 32FS Installation And Operation Manual page 15

Free-standing pellet stove elite series
Hide thumbs Also See for Montage 32FS:
Table of Contents

Advertisement

Standard Horizontal Installation Configurations
Montage™ 3FS
Figure 16 - Montage 32FS, Corner Through the Wall
6" (15 mm)
Minimum
Figure 17 - Montage 32FS, Parallel Through the Wall
3" (75 mm) Minimum clearance
between wall and pipe. If you vent to
the furthest wall, the vent pipe must
maintain a 3" clearance parallel to
the other wall.
1" Min.
Wall
Hearth Pad / Floor Protection
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Top View Illustration
1" Min.
Wall
Notes:
• It is not recommended to terminate
Note: Horizontal run of pipe requires
1/4" (7 mm) rise per foot.
" (51 mm)
Minimum
Wall
exhaust vent on the prevailing wind
side of the house.
Outdoors
45 Degree
Elbow
1" (305 mm)
Minimum From
Outer Wall
1"(305 mm) From
Ground or Other Surface
15