COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
INDOOR COIL MODEL NO.
ID CFM
CONDENSER
ENTERING AIR
ID DB (°F)
TEMPERATURE
ID WB (°F)
T.C.
65
S.C.
K.W.
T.C.
75
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
T.C.
105
S.C.
K.W.
T.C.
115
S.C.
K.W.
T.C.
125
S.C.
K.W.
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
LOW CFM
Air Handler
Coil
AV36
AV/SV48
MV12B
FC/MC35B
MV12B
FC/MC42B
MV20D
FC/MC48D
20
CZE03611
FC/MC48C + MV16C
750
80
80
75
80
57
62
62
67
26.9
27.8
26.7
30.6
25.7
25.5
20.0
20.1
1.2
1.3
1.2
1.2
25.1
26.1
25.4
28.8
24.3
23.9
19.3
19.4
1.5
1.5
1.5
1.4
23.2
24.4
24.1
27.0
23.0
22.4
18.6
18.7
1.7
1.7
1.7
1.7
21.3
22.7
22.8
25.2
21.7
20.9
17.9
18.1
2.0
2.0
2.0
1.9
20.3
21.3
21.2
23.6
20.6
19.7
17.1
17.4
2.3
2.3
2.3
2.3
19.4
20.0
19.7
22.0
19.6
18.5
16.3
16.7
2.6
2.6
2.6
2.6
18.4
18.7
18.3
20.5
18.6
17.4
15.5
16.1
3.0
2.9
3.0
2.9
T.C.
S.C.
KW
0.97
0.94
0.96
1.00
1.00
1.00
0.97
0.94
1.01
0.97
0.94
1.01
1.00
1.01
1.00
800
80
80
80
75
72
57
62
62
31.8
27.4
27.9
27.1
30.8
16.1
26.3
24.9
20.7
20.9
1.2
1.2
1.2
1.3
1.2
30.6
25.6
26.2
25.7
29.0
15.5
24.9
23.8
20.0
20.2
1.4
1.5
1.5
1.5
1.4
29.3
23.8
24.6
24.3
27.2
15.0
23.6
22.7
19.3
19.4
1.7
1.7
1.7
1.7
1.7
28.1
22.0
23.0
23.0
25.4
14.4
22.3
21.7
18.6
18.7
1.9
2.0
2.0
1.9
1.9
26.2
20.9
21.6
21.5
23.7
13.8
21.2
20.4
17.7
18.0
2.2
2.3
2.3
2.3
2.3
24.3
19.8
20.2
20.0
22.1
13.2
20.1
19.1
16.9
17.3
2.6
2.6
2.6
2.6
2.6
22.4
18.7
18.7
18.5
20.5
12.6
19.0
17.8
16.1
16.7
2.9
2.9
2.9
2.9
2.9
Variable Speed
Coil
Furnace
PV8*B16
FC/MC/PC35B
P(C,V)9*B12
FC/MC/PC35B
PV8*C16
FC/MC/PC35C
PV8*C20
FC/MC/PC35C
P(C,V)9*C16
FC/MC/PC35C
P(C,V)9*C20
FC/MC/PC35C
PV8*B16
FC/MC/PC42B
P(C,V)9*B12
FC/MC/PC42B
PV8*C16
FC/MC/PC42C
PV8*C20
FC/MC/PC42C
P(C,V)9*C16
FC/MC/PC42C
P(C,V)9*C20
FC/MC/PC42C
PV8*C16
FC/MC/PC48C
PV8*C20
FC/MC/PC48C
P(C,V)9*C16
FC/MC/PC48C
P(C,V)9*C20
FC/MC/PC48C
P(C,V)9*D20
FC/MC/PC48D
PV8*C20
HC42
P(C,V)9*C20
HC42
PV8*C20
HD48
P(C,V)9*C20
HD48
Continued on Page 21.
850
80
80
80
80
75
67
72
57
62
62
32.3
28.0
27.9
27.4
16.4
26.8
24.3
21.3
1.2
1.2
1.2
1.3
31.0
26.2
26.4
26.0
15.9
25.5
23.7
20.6
1.4
1.5
1.5
1.5
29.7
24.4
24.9
24.6
15.4
24.3
23.1
19.9
1.7
1.7
1.7
1.7
28.4
22.7
23.4
23.2
14.9
23.0
22.4
19.2
1.9
1.9
1.9
1.9
26.4
21.5
21.8
21.7
14.2
21.8
21.0
18.3
2.2
2.3
2.3
2.3
24.5
20.3
20.3
20.2
13.6
20.6
19.7
17.5
2.6
2.6
2.6
2.6
22.6
19.1
18.8
18.7
12.9
19.4
18.3
16.6
2.9
2.9
2.9
2.9
T.C.
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
1.00
1.00
1.00
1.00
1.00
0.98
0.98
0.98
0.98
Johnson Controls Unitary Products
80
80
67
72
31.1
32.7
21.7
16.8
1.2
1.2
29.2
31.3
20.9
16.3
1.4
1.4
27.4
30.0
20.1
15.9
1.7
1.7
25.5
28.6
19.3
15.5
1.9
1.9
23.9
26.6
18.6
14.7
2.3
2.2
22.2
24.6
17.9
13.9
2.6
2.6
20.6
22.7
17.2
13.2
2.9
2.9
S.C.
KW
0.96
1.01
0.94
1.03
0.94
1.03
0.94
1.03
0.94
1.03
0.94
1.03
0.96
1.01
0.94
1.03
0.94
1.03
0.94
1.03
0.94
1.03
0.94
1.03
1.02
1.00
1.02
1.00
1.01
1.01
1.01
1.01
1.01
1.01
0.94
1.03
0.94
1.03
0.94
1.03
0.94
1.03