Lennox Hearth Products Villa Vista Installation & Operation Manual
Lennox Hearth Products Villa Vista Installation & Operation Manual

Lennox Hearth Products Villa Vista Installation & Operation Manual

Wood-burning fireplaces signature collection

Advertisement

SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNINGS
Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
Carefully supervise children in the
same room as appliance.
Listed to standards:
ULC-S610 & UL-127
Report No. 192-5237
INSTALLATION AND

OPERATION INSTRUCTIONS

Wood Burning Fireplaces
P/N 850,028M REV. J 11/2008
MODEL
Villa Vista
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and
understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including
but not limited to the fireplace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
Lennox Hearth Products wood-burning fireplaces are designed for use
as a supplemental heater. They are not intended for continuous use
as a primary heat source.
The fireplace cannot be operated without a door.
Consult your dealer to select the correct door
model.
Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
Install the fireplace only as described in these
instructions.
PI VILLA VISTA REV. 4 NOV 2008
VILLA VISTA™
WARNINGS
TM

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products Villa Vista

  • Page 1: Operation Instructions

    Lennox Hearth Products wood-burning fireplaces are designed for use as a supplemental heater. They are not intended for continuous use as a primary heat source.
  • Page 2: Safety Rules

    IMPORTANT! GENERAL SAFETY PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY RULES BEFORE YOUR FIRST FIRE. WARNING The Villa Vista™ fireplace must be installed with an outside air kit intake, which is included with the fireplace WARNING THE FIREPLACE MUST BE OPER- ATED WITH THE DOORS FULLY OPENED OR DOORS FULLY CLOSED.
  • Page 3: Table Of Contents

    In selecting this Lennox Hearth Products wood-burning appliance you have chosen one of the finest fireplaces available. The Villa Vista™ wood fireplace is a clean burning EPA certified fireplace that is designed to provide you dependable service as well as warmth and enjoyment for many years to come.
  • Page 4: Operating The Fireplace

    Combustion Control There is no flue damper in the Villa Vista fire- place. As is common with air tight stoves, the combustion air damper controls the air enter- ing the firebox. This allows for a more precise control of the fire.
  • Page 5: Starting And Maintaining A Fire

    Refuelling for Best Performance (see Figure 5) To refuel the Villa Vista fireplace at the end of a burn cycle when only hot embers remain and flames are gone (not enough heat to maintain catalyst operating temperatures): Step 1.
  • Page 6: Smoking - Causes And Troubleshooting

    10 minutes before closing it. It will ensure sufficient tem- peratures for combustor light-off. To refuel the Villa Vista™ fireplace when the unit is still hot (Some burning fuel remaining or a glowing combustor) Step 1. Open the by-pass and air controls fully.
  • Page 7: Door Frame Care

    ROTATE ROTATE Figure 6 Figure 7 ROTATE 1. Front Refractory 2. Bottom Refractory 3. Left Side Refractory 4. Right Side Refractory 5. Back Refractory NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Cleaning Procedure (see Figure 6): Rotate the retainers to release the com- bustor support plate while holding it to make sure it does not drop.
  • Page 8: Door Installation

    Turning the screw clockwise will increase air tightness. Glass Care - Replacement The glass used for the Villa Vista fireplace is a high temperature ceramic glass (1,400° F / 760° C). If the glass breaks, it must be replaced with a ceramic glass.
  • Page 9: Framing, Facing And Mantel

    Hearth Extension Requirements The Villa Vista™ fireplace may be installed directly on a combustible floor. The supplied safety metal strip must be positioned as fol- lows: One half under the front of the fireplace...
  • Page 10: Fireplace / Framing Dimensions

    Corner Installation 21-1/4" 19-17/32" Back Wall of Chase/Enclosure Including Finising Materials if any Rough Framing Face (Unfinished Shown) * Zero Clearance From Back Spacer to Wall Combustion Air Kit FRAMING DIMENSIONS Fireplace Opening Width 38-1/4" 972 mm 47-3/8" 1203 mm 30-1/16"...
  • Page 11: Insulated Chase Construction

    INSULATED CHASE CONSTRUCTION UNIVERSAL SUPPORT WITH STRAP ATTACHED TO JOIST ATTIC RADIATION SHIELD FIRESTOP 7 ft. min. 6'8" min 1/2" PLYWOOD Figure 12 STORM COLLAR FLASHING CEILING/FLOOR SEPARATION MUST HAVE SAME FIRESTOPPING RESISTANCE AS ADJACENT WALL. MUST HAVE THE SAME INSULATION AS ADJACENT CEILING.
  • Page 12: Facing / Mantel

    Facing 1. Combustible wall (such as drywall panels) must be installed flush with the fireplace. It may not project in front of and on the fireplace (i.e. the steel facade of the fireplace (see Figure 13). 2. Decorative frame made of combustible material cannot project in front of and on the fireplace steel front, in the space delimited by the width of the unit (38") and a height of 54"...
  • Page 13: Hot Air Ducting Installation

    68" (1727 mm) Maximum length - See Figure 17 The height of the louver must be measured from the base of the Villa Vista™ fireplace to the middle point of the louver. When installing the double outlet system, the hot air outlets can be installed in the same room as the fireplace, or one or both of the outlets can be installed in adjacent or upper rooms.
  • Page 14 A furnace duct is only single wall and not double wall as is required for the Villa Vista™ fireplace hot air exhaust. 7. Use only Lennox Hearth Products grills and components as described in this manual. Other grills or registers, for example, may be too restrictive and may overheat the fireplace or ceiling.
  • Page 15: Outside Air Kit

    OUTSIDE AIR KIT During operation, the fireplace requires fresh air for combustion and draws air from outside the house. It may starve other fuel burning appliances such as gas or oil furnaces. As well, exhaust fans may compete for air, caus- ing negative pressure in the house, resulting in smoke entering the house from the fireplace.
  • Page 16: Chimney System

    2. The Lennox fireplace model VILLA VISTA™ fireplace is listed only with Security Chimneys International Ltd. 7" diameter chimney systems models ACBI or ASHT+ or S2100+.
  • Page 17: Acbi Chimney

    ACBI CHIMNEY INSTALLATION RAIN CAP COLLAR FLASHING ATTIC RADIATION SHIELD OPTIONAL CHIMNEY Chimney Outside OUTSIDE AIR INTAKE Air Intake (REQUIRED WITH (required when ACBI CHIMNEY using ACBI chimney) INSTALLATION) Figure 22 CHIMNEY INSTALLATION INSTRUCTIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 23).
  • Page 18: Offset Chimney Installation

    COLLAR FLASHING Figure 25 UNIVERSAL SUPPORT (AC10SU) Figure 26 Roof Down Slope Hole Size Degree Of ACBI ASHT+ Slope 7" 15" 13-3/8" (380mm) (340mm) 2/12 15-5/8" 13-5/8" (390mm) (345mm) 4/12 16-1/8" 14-1/8" (410mm) (359mm) 6/12 15" 15" (380mm) (380mm) 8/12 18-1/4" 16-1/8" (465mm) (410mm) 10/12...
  • Page 19: Angled Wall Radiation Shield

    DEVIATION ONE LENGTH BETWEEN ELBOWS CHIMNEY & ELBOW 7” 12" LENGHT 5 1/2" DEVIATION (140 mm) (178 mm) 32 1/4" LENGTH (819 mm) (965 mm) ACBI 10 1/2" 13 1/2" DEVIATION (267 mm) (343 mm) 35 3/8" 30 1/8" LENGTH (765 mm) (899 mm) DEVIATION...
  • Page 20: Chimney Support Installation

    CHIMNEY SUPPORT INSTALLATION Universal Roof Support This support has two possible uses: For ASHT+ it must be used on a roof to support the chimney. It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset.
  • Page 21: Masonry Applications

    INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATIONS WARNING Before starting the installation, the masonry chimney must be inspected by a qualified chimney sweep. The following requirements must be met: The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing bricks that could inhibit correct installation of the liner.
  • Page 22: Parts And Components List

    7B30ZK-1 Blower Blower Motor Speed Control Rigid Firescreen 7B30ZO 7B30ZGB 7B26ZE90 Fireplace Model VILLA VISTA - Approved Venting Components 7B26ZE45 7B26ZLA 7" Diameter Chimney - Model ASHT+, S2100+, HT6000+, HT6103+ or ACBI 7B26ZL2A manufactured by Security Chimneys International only. 7B26ZR 7"...
  • Page 23 VILLA VISTA™ COMPONENTS LISTS ACBI Chimney (AC - Air Cooled - 7" I.D., 13" O.D.) Description Lengths and Misc. Chimney Components 12" Length, 7" Dia., ACBI7L12 18" Length, 7" Dia., ACBI7L18 36" Length, 7" Dia., ACBI7L36 48" Length, 7" Dia., ACBI7L48 15° Elbow, 7" Dia., ACBI7E15 30° Elbow, 7" Dia., ACBI7E30 Rain Termination Cap (regular), 7"...
  • Page 24 VILLA VISTA™ COMPONENTS LISTS Secure Temp™ ASHT 1" - High Temperature Insulated Stainless Steel Chimney System (7" ID and 11" OD) Description Lengths and Misc. Chimney Components Length 8", 7L8 Length 12", 7L12 Length 18", 7L18 Length 24", XL24 Length 36", 7L36 Length 48", 7L48...
  • Page 25: Replacement Parts

    VILLA VISTA™ COMPONENTS LISTS Replacement Parts Description Back Refractory Right Side Refractory Left Side Refractory Bottom Refractory Ash Lip Wooden Door Handle Wooden Handle By-pass Ceramic Glass Panel Hinge Kit Secondary Air Tube (rear) Catalyst Air Tube (front) Cast-iron Log Supports (2)
  • Page 26: Product Reference Information

    Your Dealer's Name _________________________________________________ Your Dealer's Phone Number __________________________________________ Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.