Non-concealed gas connections may be made using the entry points
on the base of the firebox. A concealed gas connection may be made
using the knockout hole in the center back of the firebox. Select the most
appropriate entry point and knock out the relevant hole.
If a concealed gas connection is to be made, the supply pipe should always
be sleeved through walls and floors using the shortest possible route.
For concealed supply pipe routing, pipes must (where possible) be ver-
tical and providing there is sufficient wall thickness available, they should
be placed in pipe chases. Horizontal pipe runs should be avoided where
possible. Prior to chasing a solid wall, an inspection should be made
to note the proximity of any cables/sockets outlets which may already
be buried. Pipes must be secured using suitable clips and protected
against corrosion. Ideally factory finished protected pipe-work and fittings
should be used. Joints should be kept to a minimum and compression
fittings must not be used. The pipe-work installation must be tested for
soundness before any protection is applied and/or the pipe-work and
fittings are buried.

11.0 MOUNTING THE APPLIANCE

After having selected the final mounting position of the appliance, taking
into account the site requirements as specified in Section 8 of these instruc-
tions, the integrity of the wall, and the feasibility of the proposed supply
pipe routing, the firebox of appliance may be secured to the wall.
To ensure customer safety, be sure to design the installation so that the
strength of both the wall and any wall fixings used are sufficient. Lennox
Hearth Products assumes no responsibility for injuries and damages that
may occur due to improper installation or handling.
The appliance should not be installed until all dry wall sanding and wall
painting has been completed.
FocalPointFires Single
WARNING
CLEARANCES FROM COMBUSTIBLE MATERIALS
The following clearances must be maintained at all times.
Failure to do so may result in the risk of a fire.
For full information refer to the instruction manual
provided with the heater.
Clearance to combustible ceiling
32" measured from top of appliance
glass panel
Clearance in
Clearance to
front of
combustible
heater 20"
sidewalls 4"
(both sides)
Note : Zero clearance from bottom of heater frame
required for hard combustible floors. Minimum 4"
clearance required to rugs or any fabric floor
coverings. REFER TO INSTRUCTION MANUAL
IMPORTANT : Fabrics, curtains and drapes are not
permited above the heater at any distance and within
20" of the heater sides. No combustible shelves of any
size are permitted above the heater.
F860041/A
ADVERTENCIA
ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES
Deben mantenerse en todo momento los siguientes espacios
libres. El no hacerlo puede causar un riesgo de incendio.
Consulte el manual de instrucciones suministrado con este
aparato para obtener información completa.
El espacio de 32" hasta un techo
combustible se mide desde el borde
superior del panel de vidrio del aparato
Espacio libre
Espacio hasta
delante del
paredeslaterales
calentador 20"
combustibles
4" (ambos lados)
Nota: No se requiere espacio libre desde el borde inferior del
marco del calentador en caso de pisos combustibles duros.
Se requiere un espacio mínimo de 4" entre el calentador y
cualquier alfombra, moqueta o revestimiento de suelo de
tela. CONSULTE EL MANUAL DE INSTRUCCIONES.
IMPORTANTE: No se permite la colocación de telas, cortinas y
similares por encima del calentador a cualquier distancia, ni a
una distancia de 20" de los laterales del calentador. No se
permiten estantes combustibles de cualquier tamaño por
encima del calentador.
F860041/A
DO 005855/0 - ISSUE A
Figure 2 - Wall Fixing Template
24/04/08
DO 005855/0
Lennox L40 Scandium fitting template
POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL
COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED
FIXING POINTS
PIERCE TEMPLATE TO MARK HOLE POSITION ON WALL X 4
PUNTOS DE SUJECION
PERFORE LA PLANTILLA PARA MARCAR LA POSICION DE LOS 4 TALADROS EN LA PARED
Scandium
WALL MOUNTED VENT FREE FITTING TEMPLATE
PLANTILLA PARA LA INSTALACION DE CHIMENEAS DE PARED SIN SALIDA DE HUMOS
IMPORTANT
THIS APPLIANCE IS TO BE WALL HUNG ONLY.
DO NOT RECESS OR INSET ANY PART OF THE APPLIANCE.
THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY.
DO NOT INSTALL THE APPLIANCE WITH THIS TEMPLATE IN PLACE.
FIXING POINTS
PUNTOS DE SUJECION
Ref. Paul West - Focal Point Fires. Any problems please call 01202 588629
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
The wall where the appliance is to be installed must
be capable of long-term support of the total load of
the appliance. Measures should also be taken to
ensure sufficient strength to withstand the force of
earthquakes, vibration and other external forces.
Incorrect installation can cause the appliance to fall from the wall and
cause injury. Do not block the ventilation holes of the appliance. The
wall onto which the appliance is installed must be flat. Install only on a
vertical surface. Avoid sloped surfaces. Installation onto anything other
than a vertical wall may result in fire, damage or injury.
A full size fitting template is supplied to assist with wall mounting.
Mark the positions shown as "Fixing Points" on the wall. If the appli-
ance is to be mounted on the inner leaf of a conventional cavity wall,
or a solid wall, drill four holes using a 5/16" masonry bit, to a depth of
1-11/16". Insert the wall plugs provided.
If the appliance is to be mounted on a dry lined wall or a timber framed
construction wall then special cavity screw fixings will be required which
are not supplied with this product. These should be constructed from
metal and not plastic.
If a concealed gas connection is to be made ensure the gas supply pipe
is in it's final position and can enter the appliance in the correct position
when the appliance is hung on the wall.
Artwork Size: W1055 x H530
16" (406mm)
IMPORTANTE
ESTE APARATO UNICAMENTE DEBE SER COLGADO EN UNA PARED.
NO EMPOTRE NINGUN ELEMENTO DE ESTE APARATO.
ESTA PLANTILLA SIRVE UNICAMENTE PARA MARCAR LOS PUNTOS DE FIJACION.
RETIRE LA PLANTILLA ANTES DE COLOCAR LE APARATO.
CONCEALED
GAS INLET
ENTRADA DE
GAS OCULTA
WARNING
7