Chimney Installation Instructions - Lennox Hearth Products MONTECITO ESTATE MONTEST Installation And Operating Instructions Manual

Epa wood-burning fireplace signature collection
Table of Contents

Advertisement

CHIMNEY INSTALLATION INSTRUC-
TIONS
1. Cut and frame the holes in the ceiling, fl oor
and roof where the chimney will pass (see
Figure 22). Use a plumb bob to line up the
center of the holes. The sizes are indicated
in Table 2 for the fl oor and ceiling holes
and Table 3 (Page 15) for the roof holes.
CHIMNEY MODEL
Secure Temp™ S2100+
Nova Temp™ HT6000+
Secure Temp GX
ACBI: Ceiling
(1" clearance)
Wall
Note: See Table 3 for Sloped Roof Framing
Table 2 - Flat Roof Framing
Figure 22 - Roof Framing
From below, install a fi restop in each ceiling/fl oor
separation through which the chimney will pass.
At the attic level, install an attic radiation shield
from above (Figures 23a & 23b).
2. For Secure Temp S2100+ / Nova Temp
HT6000+ / Secure Temp GX chimneys, place
the fi rst chimney length on the fi replace.
To lock it in place, turn 1/4 of a turn clock-
wise. With the ACBI chimney, you must
use a starter section before installing the
fi rst chimney length (Figure 24). Continue
installing chimney lengths making sure to
lock each length in place.
3. Every time the chimney passes through a ceil-
ing or a wall, install the appropriate fi restop.
When you reach the desired height, install the
roof support (Refer to instructions included
with the support). For an ACBI chimney use
an universal support AC10SU.
4. Put the roof fl ashing in place and seal the
joint between the roof and the fl ashing
with roofi ng pitch (see Figures 25 & 26).
For sloping roofs, place the fl ashing under
the upper shingles and on top of the lower
shingles. Nail the fl ashing to the roof, using
roofi ng nails.
5. Place the storm collar over the fl ashing, and
tighten it with the bolt supplied. Finally, seal
the joint between the storm collar and the
chimney, using silicone caulking.
6. Install the chimney cap.
14
SQUARE HOLE
SIZE OPENING
15 in (380 mm)
15 in (380 mm)
17 in (432 mm)
Figure 23a
CHIMNEY INSTALLATION
MODEL ACBI
Optional Chimney
Outside Air Intake
Figure 24
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
S2100 / HT6000+
Solid Packed Pipe
Attic Radiation Shield
Firestop
Outside Combustion
Air Kit
ACBI
Air Cooled Pipe
Attic Radiation
Shield
Radiation Shield
Figure 23b
Rain Cap
Collar
Flashing
Attic Radiation
Shield
Firestop
Universal Support
ACBI Starter Section
ACBI7SB
or
ACBI7SB30
Note: Outside air kits must be
installed for both fi replace and
ACBI chimney.