Lennox Hearth Products MPB3328CNE Installation Instructions Manual
Lennox Hearth Products MPB3328CNE Installation Instructions Manual

Lennox Hearth Products MPB3328CNE Installation Instructions Manual

B-vent mpb-33/35/40/45 series b-vent gas fireplaces

Advertisement

Quick Links

RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes. This appliance is only for use with
the type of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
WARNING: IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED EXACTLY, A FIRE
OR EXPLOSION MAY RESULT CAUSING PROP-
ERTY DAMAGE, PERSONAL INJURY OR LOSS
OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other fl ammables or liquids in the vicinity of
this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call
the fi re department.
Installation and service must be performed by
a qualifi ed installer, service agency or the gas
supplier.
OTL Report No. 116-F-36-5
INSTALLATION
INSTRUCTIONS
B-VENT
MPB-33/35/40/45 SERIES
B-VENT GAS FIREPLACES
P/N 850,033M REV. B 05/2006
MODELS
Millivolt Models
MPB3530CPM
MPB3328CNM
MPB4035CNM
MPB3328CPM
MPB4540CNM
MPB3530CNM
A French manual is available upon request. Order P/N 850,033CF
Ce manuel d'installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 850,033CF.
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN
SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE
NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE
D'INCENDIE OU POUR ÉVITER TOUT DOMMAGE
MATÉRIEL, TOUTE BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni
utiliser d'essence ni d'autre vapeurs ou liquides
infl ammables dans le voisinage de cet appareil ou
de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez
une odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le batiment
où vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un
qualifi é installeur, agence de service ou le fournis-
seur de gaz.
Electronic Models
MPB3328CNE
MPB4035CNE
MPB3530CNE
MPB4540CNE

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products MPB3328CNE

  • Page 1 MPB-33/35/40/45 SERIES B-VENT GAS FIREPLACES P/N 850,033M REV. B 05/2006 MODELS Millivolt Models MPB3530CPM MPB3328CNM MPB3328CNE MPB4035CNM MPB3328CPM MPB3530CNE MPB4540CNM MPB3530CNM A French manual is available upon request. Order P/N 850,033CF Ce manuel d’installation est disponible en francais, simplement en faire la demande.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Packaging ...Page 2 Introduction ...Page 2 General Information ...Page 2 Location ...Page 4 Appliance Clearances ...Page 4 Fireplace Specifi cations ...Page 5 Gas Vent Rule ...Page 5 Framing Specifi cations ...Page 6 Typical Installation Sequence ...Page 6 Installing The Fireplace ...Page 7 Vent System Installation ...Page 8 Field Wiring ...Page 8...
  • Page 3 Offset Venting Outside Air Kit can be installed as shown in Figure 1a. Figure 1b WARNING These fi replaces are vented deco- rative gas appliances. Do not burn wood or other material in these appliances. These appliances are designed to operate on natural or propane gas only.
  • Page 4: Location

    Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the fl u with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the appliance and have it serviced by a qualifi ed professional, as it may not be operating correctly.
  • Page 5: Fireplace Specifi Cations

    FIREPLACE SPECIFICATIONS ELECTRICAL INLET (See Also Right Side View) 5-1/2 (140) OUTSIDE AIR SHUTTER 9-3/8 (238) GAS INLET 8-15/16 (See Also (227) Right Side View) ELECTRICAL 7-3/8 INLET (187) (Optional) Left Side View 33-1/8 MPB3328 . n i MPB3530 . n i MPB4035 .
  • Page 6: Framing Specifi Cations

    FRAMING SPECIFICATIONS Header Fireplace Framing Figure 6 Back Wall of Chase/Enclosure Including Finishing Materials if any Framing Face (Unfinished Shown) Inside Chase Figure 7 Back Wall of Chase/Enclosure Including Finishing Materials if any Framing Face (Unfinished Shown) Corner Installation Figure 8 33-1/8 MPB3328 .
  • Page 7: Installing The Fireplace

    2. Measure the square footage of the fl oor space to be occupied by the system, surrounds and hearth extensions. 3. Note the fl oor construction, i.e. 2 x 6’s, 2 x 8’s or 2 x 10’s, single or double joists, type and thickness of fl...
  • Page 8: Vent System Installation

    Step 4. INSTALL THE VENT SYSTEM & EXTERIOR TERMINATION In the United States, vent installation must conform with local building codes. In the ab- sence of local codes, vents must be installed in accordance with the current edition of the National Fuel Gas Code (ANSI-Z223.1).
  • Page 9 B. Electronic Wiring (See Figures17 or 18) – Note: The electronic appliance must be con- nected to the main power supply. A junction box is located at the rear of the con- trol compartment on either side of the cabinet. The junction box on the right side contains a factory installed and wired outlet box (duplex receptacle).
  • Page 10: Connecting Gas Line

    Step 7. CONNECTING GAS LINE Make gas line connections. All codes require a shut-off valve mounted in the supply line. Figure 19 illustrates two methods for connecting the gas supply. The fl ex-line method is acceptable in the U.S., however, Canadian requirements vary depending on locality.
  • Page 11: Installing Logs

    Step 9. INSTALLING LOGS, DECORA- TIVE VOLCANIC STONE AND GLOW- ING EMBERS WARNING Logs get very hot and will remain hot up to one hour after gas supply is turned off. Handle only when logs are cool. Turn off all electricity to the appliance before you install grate and logs.
  • Page 12 Glowing Embers, Vermiculite, Decorative Volcanic Stone And Log Placement Instructions: Step 1. Separate the Glowing Embers (Rockwool) into pieces about the size of a quarter (see Figure 25). Keep the pieces fl uffed up, not matted. MPB-3328 & MPB-3530 Models - Distribute these pieces over the burner as shown in Figure 26.
  • Page 13 Figure 28 MPB-3328 LOG PLACEMENT * Item * Item numbers above correspond to photos Position the individual logs as shown below. Logs should be placed in the order shown. Position the rear log on the brackets at the rear of the fi rebox with the log's notches directly over the brackets. Position the right log (log no.
  • Page 14 Figure 29 MPB-3530 LOG PLACEMENT Catalog Number * Item * Item numbers above correspond to photos Position the individual logs as shown below. Logs should be placed in the order shown. Position the rear log on the brackets at the rear of the fi...
  • Page 15 MPB-4035 & MPB-4540 LOG PLACEMENT Figure 30 Catalog Number * Item * Item numbers above correspond to photos Position the individual logs as shown below. Logs should be placed in the order shown. Position the center log on the burner fi rst, then place the glowing embers as shown in Fig- ure 27.
  • Page 16: Appliance Operation

    Step 10. CHECKING APPLIANCE OPERA- TION With gas line installed run initial system check- out before closing up the front of the unit. Follow the pilot lighting instructions provided in the Homeowner's Care and Operation Instructions. For piezo igniter location see Figure 31 Note: Instructions are also found on the litera- ture tag attached to the gas valve train.
  • Page 17: Burner Adjustments

    Step 12. BURNER ADJUSTMENTS Note - The air shutter for the burner primary air opening is factory-set. Do not adjust the factory-set position. The factory-set position is shown in Figure 35. Main Burner Factory Air Shutter Opening Setting - Inches (millimeter) Model Natural Propane...
  • Page 18: Finishing Requirements

    (356) (305) (254) (203) NOTE - Hood shown as positioned in louvered front model. The hood position in the flush faced front model is lower than shown. *Note - The side walls of mantels may protrude beyond the front face of the fireplace a maximum of 5 inches (127mm) at 0 inch clearance to the sides of the fireplace.
  • Page 19: Gas Conversion Kits

    GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer's instructions and all applicable codes and require- ments of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fi...
  • Page 20 b. Attach manometer to the manifold side pressure test fi tting and verify manifold pres- sure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column (2.49 kPa) for propane gas. c. Refer to Figure 40 and remove the pilot hood assembly to access the hexed pilot orifi...

This manual is also suitable for:

Mpb3328cnmMpb3328cpmMpb3530cnmMpb3530cpmMpb4035cnmMpb4540cnm ... Show all

Table of Contents