Chimney Requirements; Installation Procedures-Masonry Chimney - Lennox Hearth Products CANYON C310 Installation And Operation Manual

Epa certified wood-burning fireplace insert country collection
Hide thumbs Also See for CANYON C310:
Table of Contents

Advertisement

CHIMNEY REqUIREMENTS

The Canyon™ C310 inserts are approved for use in masonry fireplaces
built to UBC Chapter 37 or equivalent with a minimum 30-1/2" (775)
width opening at the front of the fireplace.
The Canyon™ C310 inserts may be installed using 6" chimney in vertical
installations utilizing a 8" to 6" reducer (cat. # 71134) at the flue collar. If
the venting system is all vertical and the total vent length above the flue
outlet exceeds 14 feet, it is recommended that the 8" to 6" pipe reducer
is used and a 6" venting system be installed.
Do not remove brick or mortar from masonry fireplace to accommodate
insert. Approved with or without positive flue connection. Approved
with minimum 6" (152 mm) diameter stainless steel listed reline system.
Country Collection inserts are tested to UL 1482 / ULC S628 and listed
by OMNI-Test Laboratories, Inc.; Portland, OR.
IMPORTANT NOTE: See Draft Requirements and Selecting a Proper
Venting System on Page 4 to assist you in choosing the proper venting
system for your installation.
Remove and clean behind unit frequently, as creosote build up may
occur rapidly.
INSTALLATION PROCEDURES - MASONRY CHIMNEY
Note: Although not required, a full-length stainless steel liner is recom-
mended for optimum safety and performance. See your Lennox Hearth
Products dealer for details.
Note: When installing your stove with a positive flue connection, be
sure to leave the insulation off the surround panels (flanges) and leave
a 1/4" (6 mm) airspace insulation off the surround panels and the facing
of your fireplace.
1. READ ENTIRE INSTALLATION INSTRUCTIONS.
2. Check all REqUIRED CLEARANCES as specified in the previous section
(Page 7) of this installation instruction booklet.
3. Wear gloves during installation in case of sharp edges on the stove
and it's parts.
4. Open or remove the existing fireplace damper. Make sure the damper
cannot fall closed.
5. Install the two 1/2" x 3" (13 mm x 76 mm) leveling bolts -heads up- a
few turns in the leveling nuts on each side of the outer chamber of the
insert at the lower rear corners.
6. Position the insert in the center of the fireplace opening and push it
back until the surround brackets are approximately 2" (51 mm) away
from the fireplace front.
7. Install the side surround panels and push the insert up snug against
the fireplace face. Then with the location selected remove the sur-
round panels and level the stove with the leveling bolts using a 3/4"
(19 mm) socket, extensions (to reach the bolt head) and a ratchet.
8. Glue the insulation around the outer edge of both the top and side
surround panels.
9. Install the surround panels loosely, align and tighten. Check for a
tight fit against the fireplace.
10. Install the brick and baffle as per instructions on Page 6.