Clearing Tip Clogs; Watchdog ™ Protection System; Ironman Units Only) - Graco GMAX 3400 Operation

Airless sprayer
Hide thumbs Also See for GMAX 3400:
Table of Contents

Advertisement

Clearing Tip Clogs

To avoid injury, never point gun at your hand or into a
rag!
1. Release trigger, engage trigger lock. Rotate Switch
Tip. Disengage trigger lock. Trigger gun to clear
clog.
ti13033a
ti10166a
ti13033a
2. Engage trigger lock. Return Switch Tip to original
position. Disengage trigger lock and continue spray-
ing.
ti10166a
ti13034a
332919C
WatchDog
WatchDog
(ProContractor and Ironman units only)
Pump stops automatically when material pail is empty.
To Activate:
1. Perform Startup.
2. Turn WatchDog switch ON and WD ON displays.
ti10167a
3. Turn WatchDog switch OFF. Add material or reprime
ti10167a
Protection System (ProContractor and Ironman units only)
Protection System
EMPTY displays/flashes and pump stops when
Watchdog protection system detects an empty
material pail.
ti22711a
sprayer. Turn pump switch OFF and ON to reset
WatchDog protection system. Turn WatchDog
switch back ON to continue to monitor material
level.
ti22712a