Startup

1. Place suction tube and drain tube in grounded metal
pail partially filled with flushing fluid. Attach ground
wire to pail and to earth ground.
2. Turn prime valve down to DRAIN position. Turn
pressure control counterclockwise to lowest pres-
sure.
ti14842a
3. Set pump switch OFF.
ti5790a
4. Start Engine
a. Move fuel valve to open.
ti5248a
b. Move choke to closed.
ti5249a
332919C
ti14844a
ti22708a
c. Set throttle to fast.
ti5250a
d. Set engine switch to ON.
ti5262a
5. Pull rope to start engine.
ti5263a
6. Increase pressure enough to start pump stroking
and allow fluid to circulate for 15 seconds; turn pres-
sure down and turn prime valve forward to SPRAY
position.
7. Disengage spray gun trigger lock.
Startup
ti22709a
ti14845a
ti22818a