11
Stitch length control eccentric
.04.15
Requirement
When the needle (with maximum stitch length set), coming from TDC, is 3 mm above the
needle plate, the crank 3 must have reached its front point of reversal.
Fig. 11 - 15
● Set the maximum stitch length.
● Turn stitch length control device 1 (screws 2) according to the requirement.
2
1
3
Adjustment
11 - 19