Lenovo ThinkServer TD200x Hardware Maintenance Manual page 39

Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 8, "Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823," on page 239 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
0011002
Microprocessor mismatch
0011004
Microprocessor failed BIST
001100A
Microcode update failed
0050001
DIMM disabled
0051003
Uncorrectable DIMM error
0051006
DIMM mismatch detected
Action
1. Run the Setup utility and view the microprocessor
information to compare the installed
microprocessor specifications.
2. (Trained service technician only) Remove and
replace one of the microprocessors so that they
both match.
1. Update the firmware (see "Updating the firmware"
on page 267).
2. (Trained service technician only) Reseat
microprocessor 2.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. (Trained service technician only)
Microprocessor
b. (Trained service technician only) System
board
1. Update the server firmware (see "Updating the
firmware" on page 267).
2. (Trained service technician only) Replace the
microprocessor.
1. If the server fails the POST memory test, reseat
the DIMMs.
2. Remove and replace any DIMM for which the
associated error LED is lit (see "Removing a
memory module" on page 212 and "Installing a
memory module" on page 213).
3. Run the Setup utility to enable all the DIMMs.
4. Run the DSA memory test.
1. If the server failed the POST memory test, reseat
the DIMMs.
2. Remove and replace any DIMM for which the
associated error LED is lit (see "Removing a
memory module" on page 212 and "Installing a
memory module" on page 213).
3. Run the Setup utility to enable all the DIMMs.
4. Run the DSA memory test.
Make sure that the DIMMs match and are installed in
the correct sequence (see "Installing a memory
module" on page 213).
31