4-5. Outdoor Unit (RAS-24UA-ES-1)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor) KFG6-71SB5P-T Winding resistance (Ω)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Bimetal thermostat
6
Magnetic contactor

4-6. Outdoor Unit (RAS-18UA-ES2)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Bimetal thermostat
6
Relay
Type
Output (Rated) 2200W, 2poles, 1 phase, 220 – 240V, 50Hz
PA290X3F-4MS
Winding resistance (Ω)
(at 20°C)
Output (Rated) 65W, 6poles, 1 phase, 220 – 240V, 50Hz
(at 20°C)
451355KQ
AC 450V, 3.5µF
371456JCR
AC 370V, 45µF
CS-7C
Open 130 ± 5°C, Close 70 ± 10°C
A35
220 – 240V, 50Hz
Type
Output (Rated) 1500W, 2poles, 1 phase, 220 – 240V, 50Hz
PA225X3F-4L
Winding resistance (Ω)
(at 20°C)
Output (Rated) 42W, 6poles, 1 phase, 220 – 240V, 50Hz
HF-240-42B
Winding resistance (Ω)
(at 20°C)
451205KQ
AC 450V, 2µF
371456JCR
AC 370V, 45µF
CS-7C
Open 130 ± 5°C, Close 70 ± 10°C
VC20FA
220 – 240V, 50Hz, 1P1a
– 15 –
FILE NO. SVM-03009
Specifications
Red-Black
White-Black
1.07
Red-Black
White-Black
64.4
Specifications
Red-Black
White-Black
1.35
Red-Black
White-Black
176.2
2.20
127.4
2.68
290.5