Toshiba RAS-12KSX-1 Service Manual page 47

Air conditioner split wall type
Table of Contents

Advertisement

Table 9-6-2 Approximate resistance value of thermo sensor
Temperature
Resistance value
9-6-2.
Ho
w to shor
ten time of restart delay timer
1
Press [CLR] button while pressing [CHK] button
with a tip of a pencil.
2 Then press [ START/STOP] button to transmit the
signal to the indoor unit.
9-6-3. How to set/cancel the self cleaning function
The self cleaning function is set from a factory. To cancel this function, should keep press the
[RESET] button for 20 seconds till can hear the long combination sound and repeat the same
procedure when need to set.
0°C
10°C
33.8
20.35
20°C
12.59
MODE
TEMP.
FAN
AUTO
AUTO
COOL
QUIET
B
DRY
Hr.ON
OFF
AUTO FAN
TEMP.
START/STOP
SWING
FIX
FAN
MODE
ECO
RST CHK
TIMER
ON
OFF
SET
CLR
− 46 −
FILE NO. SVM-08029
25°C
30°C
10.00
7.99
[CHK] button
[CLR] button
(kΩ)