Causes of Faults and Suggested Remedies
1. Gas supply
In cases of miss ignition, insufficient heating and gas
smell, check that:
• The gas supply pressure is correct.
• The specified gas type is correct for the area.
• There are no breaks/escapes in gas supply.
• There is no air in the gas supply.
Check the gas pressure at both the meter and the
appliance.
Air in the gas line will prevent the appliance from
igniting.
2. Thermostat setting
When the room does not reach the selected temperature, or
the appliance will not remain alight, check that:
• The selected temperature is not set lower than the
room temperature.
Select the required temperature setting with the UP/
DOWN selection buttons.
3. Blocked air filter
If insufficient heating or lockout occurs, check that:
• The air filter is not blocked with dust.
If the air filter is blocked, the safety device will operate.
..... 14 flashing
The filter must be cleaned at least once per month.
4. Air flow obstruction
If insufficient heating or lockout occurred, check that:
• There are no obstacles in front of the appliance or
louvres.
..... 14 flashing
There should be no articles within one (1) metre of the
front of the appliance.
Energysaver RHFE-308FTR
5. Flue terminal
If flame failure occurs during normal operation, check
that:
• The flue terminal on the exterior wall is not
obstructed in any way.
..... 12 flashing
Check in particular for shrubs growing over the flue
terminal or a thick build up of spider webs.
6. Flash back protection
If flame failure occurs during normal operation, check:
• The flue terminal air intake is not blocked.
• For dust or foreign material on the burner.
• Combustion specification and gas type.
..... 12 flashing
7. Room temperature
• Is the room temperature unusually high?
10 minutes after having sensed 40°C the appliance will
automatically go out.
..... 16 flashing
8. Power failure
• If there has been a power failure for 0.2 seconds
or longer. Current time will be displayed on dis-
play when "set times" button is pressed once.
(Time will be slow by duration of power failure).
..... --:-- flashing
9. Smell of products of combustion
If there is a smell of gas or products of combustion, check
that:
• The flue manifold behind appliance has not come
undone.
The products of combustion are leaving the appliance
through the flue terminal.