Rinnai ENERGYSAVER RHFE-308FTR Service Manual page 25

High efficiency power flued gas space heater
Hide thumbs Also See for ENERGYSAVER RHFE-308FTR:
Table of Contents

Advertisement

OFF
ON/OFF Switch OFF
No
Temperature
Control ON
Yes
Solenoids SV1,2 OFF
Modulating Valve OFF
Combustion Fan OFF
Convection Fan MED
Operation/Combustion
Indicator OFF
Change from Room
& Set Temp to clock
All Indicators OFF
Convection Fan
(Less than 255 sec)
Energysaver RHFE-308 FTR
ECONOMY
Economy Switch ON
Economy Indicator ON
Room Temperature
drops max. 2  C
Economy Switch OFF
Economy Indicator OFF
Temperature Control
Operates
- 20 -
TIMER OPERATION
ON/OFF Switch ON
Timer Switch ON
Timer Indicator ON
No
Pre-Heat set
up Time
Yes
Timer indicator flashes
Normal operation start
No
Set-up Time
Yes
Normal Operation Stops