3. Warm Air Discharge Temperature Distribution
Condition:
Test gas:
Measured input:
Nominal input:
Room temperature:
Condition:
Test gas:
Measured input:
Nominal input:
Room temperature:
4. Measurement Points
Energysaver RHFE-308 FTR
< High Combustion >
Natural
12.55 MJ/h
13 MJ/h
o
25
C
24
24
45
72
56
81
62
66
68
43
42
39
< Low Combustion >
Natural
5.27 MJ/h
5 MJ/h
o
25
C
10
17
23
39
29
48
35
44
37
28
22
26
55
64
83
77
70
57
30
38
42
46
43
31
- 8 -
(Unit ∆
o
C)
9
18
36
42
45
45
(Unit ∆
o
C)
9
13
28
37
34
28