b
figure 7 .3
G
a
figure 7 .4
h
figure 7 .5
7 Unscrew the two screws
and remove the pump.
- 16 -
c
d
e
f
that hold the pump on the frame
PUMP
Reassemble the pump carrying out the removal operations in the
reverse order. When reassembling the pump, check the correct
location of the O-ring gasket in the inlet port of the pump that
seals the connection between the pump and the return water
group.

7 .4 removal electrical capacitor

warning: isolate the boiler from the mains electrici-
ty supply before removing any covering or compo-
nent .
1 Remove the front and right hand side case panels.
2 Disconnect the connector G (Figure 7.4) following the indica-
tions given on the connector box.
3 Remove the connector I of the cover box by levering with a
screwdriver in as shown in (Figure 7.6).
figure 7 .6
4 Remove the capacitor connection block J freeing it from the
hook K and pulling it as indicated by the arrow (Figure 7.7).
figure 7 .7
J
k
i