INSTALLERS INFORMATION - LOCATION

Issue 4
The following pages contain information relating
to Installation and Service. Installation and
Service must be carried out by an authorised
person only.
When positioning the heater, the main points
governing the location are:
1. Flue connection and terminal to comply with
AS/NZS 5601. Only Rinnai flue components
can be used.
2. Warm air distribution.
3. Ensuring that the area in which the appliance
is installed has adequate fixed ventilation, this
fixed ventilation must be provided as per AS/
NZS 5601.
4. The heater must not be installed where
curtains or other combustible materials could
come into contact with it. In some cases,
curtains may need restraining.
See diagram below for minimum clearances
required.
min. 300mm
min. 300mm
min. 1000mm
5. The heater is not designed to be built into
bookcases or shelves. For combustible open-
ing installations a Rinnai zero clearance kit
must be used and is available from your gas
appliance retailer.
6. This heater must be mounted on a hearth not
less than 50mm thick and at least the width
and depth of the heater.
The hearth surface must be flat and level to
support the entire heater or zero
clearance box.
If the heater or zero clearance box base are
not properly supported noise and vibration
may result.
7. A gas appliance must not be connected to a
chimney flue serving a separate solid-fuel
burning appliance.
Inbuilt - Royale ETR
min. 300mm
Note that side and vertical
clearances are measured
from the edge of the glass.
8. Before installing the heater, inspect the
chimney, flue piping and/or solid fuel burning
fire place and remove any combustible
materials.
9. A zero clearance kit is available from your gas
appliance retailer for installations into a
combustible opening.
• Mantles
A mantle is permitted providing the clearances
below are met.
150 maximum
10. Check that room ventiliation complies with
local regulations.
11. This heater has a power cord with a three pin
plug supplied. The power cord passes through
the slot in the lower left or right hand side of
the heater front assembly. Rinnai recommend
the heater be plugged into a 240V, 10A
earthed power point. The power point must be
a minimum of 300 mm to the side of the heater
(it must not be above the heater). Alternatively
- unit can be direct wired if the power supply is
to be concealed.
Consult a qualified electrician if direct wiring
is required as it must comply to AS/NZS 5601
and AS3000.
- 14 -
Issue 4- ©Rinnai