Download Print this page

Maintenance - Pentair Pool Products Mako Shark Owner's Manual

Inground suction pool cleaner

Advertisement

Maintenance

Your MakoShark Pool Cleaner requires very little maintenance. Check the following
from time to time.
It is quick and easy to open up the Oscillator's chamber. First stop the pump. Unscrew
the pipe and nut swivel and slide internal housing out of the external body. Push the
sliding lock up into open position and remove the lid. With your fi nger lift and inspect
the Oscillator and the chamber to insure that it is not obstructed with debris.
See picture:
Also insure that the Oscillator is moving freely up and down and that it is securely
clipped onto the steel pin. Then place the lid back and slide the lock down to close
and reassemble the unit.
Unscrew the nut and swivel assembly
Lid
Lock
Internal Housing
Oscillator
To remove damaged or worn Oscillator; no tools are required. Simply grab the
Oscillator, pull and waggle outward until it unclips from the steel pin. To install the
new Oscillator push it in fi rmly (TOP side up as marked) onto the steel pin until it
snaps in place. If the Oscillator is clipped in the wrong way (TOP side down) you will
not be able to close the lid.
8

Hide quick links:

Advertisement

loading