Download Print this page

Kenwood RD-HD5MD Service Manual page 7

Micro hi-fi component system
Hide thumbs Also See for RD-HD5MD:

Advertisement

1. Recordable Disc
No.
Key
1
Connect the oscilloscope to TE1 and VC in X33 pcb
2 Volume/
Select [EFBAL ADJU]
multi-control
3
Load the recordable disc
4 PLAY
[EFBAL MO-W]
5 PLAY
[EF=$✻✻MOW]
6 Volume/
Write power adjustment. Adjust the waveform as follows.
multi-control
7 PLAY
Display shows [EF=$✻✻MOR] after [EFB=✻✻xSAVE]
to save the data in E2PROM.
Mode changes write to read
Focus and disc servo are on. Tracking servo off.
8 Volume/
Read power adjustment. Adjust the waveform as follows.
multi-control
9 PLAY
Save the data in E2PROM.
Display shows [EFBAL MO-P]
Display shows [EF=$✻✻MOP]
PLAY
(Pickup travels to search pits and tune the servo to on.)
10 Volume/
Adjust the waveform as follows.
multi-control
11 PLAY
Display shows[EFB=✻✻xSAVE]
to save the data in E2PROM.
Display shows [EFBAL CD] disc motor stops.
12 EJECT
Unload disc.
2. Pre Master Test Disc(TGYS-1)
No.
Key
1
Load the disc(TGYS-1).
2 PLAY
[EF=$✻✻CD] servo is on
3 Volume/
Adjust the waveform as follows.
multi-control
4
Save the data in E2PROM.
Display shows[EFB=✻✻xSAVE] in brief time.
EF PHASE
5 EJECT
Unload disc.
During this adjustment, the oscilloscope changes in units of
about 2%. Adjust so that the waveform comes nearest to the
specified value. (MO groove read power traverse adjust-
ment)
(Traverse waveform)
Specification : A = B
Notes :
1. Data is erased during MO write when a recorded disc is
used for this adjustment.
2. If the traverse waveform is difficult to be monitored, con-
nect an oscilloscope as shown in the figure below.
330kΩ
(TE1)
10pF
(VC)
4-8 Automatic EF Balance Adjustment
• Automatic EF balance adjustment is performed.
No.
Key
1
Volume
TE B. ADJ
2
Load a recordable disc.
3
MD
TE B. MO-W (Automatic Adjustment Mode Indication)
=Low Reflection • Groove
• Writing Power
Automatic Adjustment
4
Display shows EFB = XXX SAVE in brief time and
save the data in E2PROM.
Next step
5
TE B. MO-R (Automatic Adjustment Mode Indication)
=Low Reflection • Groove
• Reading Power
Automatic Adjustment
6
Display shows EFB = XXX SAVE in brief time and
CIRCUIT DESCRIPTION
Display/Function
Display/Function
Oscilloscope
+
-
Display/Function
RD-HD5MD/HD7
No.
Key
save the data in E2PROM.
Next step
7
TE B. MO-P (Automatic Adjustment Mode Indication)
=Low Reflection • PIT
• Reading Power
Automatic Adjustment
8
Display shows EFB = XXX SAVE in brief time and
save the data in E2PROM.
Next step
9
EFBAL CHANGE (Unload a disc)
0
Load a pre-master test disc(TGYS-1).
-
MD
TE B. CD (Automatic Adjustment Mode Indication)
=High Reflection • PIT
• Reading Power
=
Display shows
EFB = XXX SAVE in brief time and
save the data in E2PROM.
EF PHASE menu
4-9 Focus Bias Adjustment
Use the special disc(continuous recorded disc)
No.
Key
1 Volume/multi-control Select [FBIAS ADJU]
2
Load the disc.
3 PLAY
[a=xx yyyy/] point a
(xx=focus bias, yyyy=C1error)
4 Volume/multi-control Adjust "yyyy" to 220 ✻
5 PLAY
[b=xx yyyy/] point b
6 Volume/multi-control Adjust "yyyy" to 220 ✻
7 PLAY
[xx yyyy/] point c
Check "yyyy" within 50
8 PLAY
Display shows [aa bb cc(xx)] focus bias adjust
(aa= point a,bb=b,cc=c )
* Notes :
1. The relation between the C1 error and focus bias value
is shown in the figure below. Points "a" and "b" in the
figure are detected by the above adjustment. Focal
position "C" is automatically obtained from points "a"
and "b" by calculation.
2. The C1 error rate fluctuates. Therefore, perform the
adjustment according to the observed mean value.
C1 error
4-10 Error Rate Check
No.
Key
1. CD Error Rate
1 Volume/
[CREC-PLAY]
multi-control
2
Load the test disc(TGYS-1)
3 PLAY
Display shows [CPLAY MID]
Access end
[c=xxxx a=yy] xxxx=C1 error (lower 20) yy=AIDP error
4 STOP
[CREC-PLAY]
5 EJECT
Unload disc.
2. MO Error Rate
No.
Key
1 Volume/
[CREC-PLAY]
multi-control
2
Load the recordable disc
3 PLAY
Display shows [CPLAY MID]
Access end
[c=xxxx a=yy] xxxx=C1 error (lower 50) yy=AIDP error(00)
4 STOP
[CREC-PLAY]
5 EJECT
Unload disc.
Display/Function
Display/Function
Focus bias value
Display/Function
Display/Function
7

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Rd-hd7md