Kenwood NX-320 Series Service Manual page 44

Uhf digital transceiver kenwood nx-320 series
Table of Contents

Advertisement

NX-320
Item
Panel tuning mode
4. Receive
* This adjustment can
Assist
be performed only
in PC test mode.
5. Transmit
* This adjustment can
Assist
be performed only
in PC test mode.
6. Frequency * This adjustment can
be performed only
in PC test mode.
44
ADJUSTMENT (K TYPE)
Condition
PC test mode
equipment
[Manual Adjustment]
1) Adj item: [Receive
Assist]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
Press [Apply All]
button to store the
adjustment value.
[Manual Adjustment]
1) Adj item: [Transmit
Assist]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [Frequency]
SSG
SSG output:
–20dBm (22.4mV)
(CW (without
modulation))
Caution:
Perform the frequency
adjustment under the
following conditions.
• Temperature
range of +20°C to
+26°C (+68.0°F to
+78.8°F).
(The temperature
is displayed on the
Frequency adjust-
ment screen of the
KPG-141D.)
• Use an accuracy
of 0.001ppm for
the SSG. (Use a
standard oscillator if
necessary.)
Measurement
Test-
Unit Terminal Unit
Panel
Panel
ANT
Adjustment
Specifi cations /
Parts
Method
[PC test
[PC test mode]
2.5V±0.1V
mode]
[Automatic Adjustment]
[ ],[ ]
1) Press [Tune
[Automatic Adjustment]
Assist Voltage]
After the auto-
button.
matic adjustment
2) Press [Apply All]
is performed, verify
button to store
that the VCO lock
the adjustment
voltage is within the
value after
voltage range which
the automatic
is specifi ed by the
adjustment has
manual adjustment.
fi nished.
[PC test mode]
[Manual Adjustment]
[Manual Adjustment]
[V] indicator on the
Press [Apply All]
PC window shows
button to store the
VCO lock voltage.
adjustment value
Change the adjust-
after all adjustment
ment value to get
points have been
VCO lock voltage
adjusted.
within the limit of
the specifi ed volt-
Note:
age.
The assist adjust-
ment value must be
Note:
between from 340
Confi rm the VCO
to 3550.
lock voltage ap-
proximately 3
seconds after the
adjustment value is
changed.
[PC test mode]
[PC test mode]
Press [Start] button
"IF20" value =
of "Auto Tuning".
Within 0±12 digits.
Press [Apply] but-
The value of "IF20"
ton to store the
will become around
adjustment value
"0" after the adjust-
after the automatic
ment has fi nished.
adjustment has
fi nished.
Remark:
"Frequency" is
adjusted under
receiving condition
with SSG.
Remarks