Air Conditioner Runs For A Short Time Only, But Room Is Not Cool; Air Conditioner Runs, But Does Not Cool; Air Conditioner Cycles On And Off Too Much Or Does Not Cool; Display Error Code - Garrison 043-6127-2 Instruction Manual

Portable
Table of Contents

Advertisement

30
Model No. 043-6127-2/043-6128-0/043-6129-8/043-6130-2/043-6131-0/043-5499-2 | Contact us: 1-800-268-6591
The current air conditioner replaced an older model.
components may cause the air conditioner to run longer than an older model,
but the total energy consumption will be less. Newer air conditioners do not emit
the" blast" of cold air you may be accustomed to from older units, but this is not
an indication of lesser cooling capacity or effciency. Refer to the effciency rating
(EER) and capacity rating (in Btu/h) marked on the air conditioner.
The air conditioner is in a heavily occupied room, or heat producing
appliances are in use in the room.
bathing and try not to use heat-producing appliances during the hottest part
of the day. Portable air conditioners are designed as supplemental cooling to
local areas within a room. A higher capacity air conditioner may be required,
depending on the size of the room being cooled.

AIR CONDITIONER RUNS FOR A SHORT TIME ONLY, BUT ROOM IS NOT COOL

Set temperature is close to room temperature.
"Portable Air Conditioner Use".

AIR CONDITIONER RUNS, BUT DOES NOT COOL

The flter is dirty or is obstructed by debris.
Air outlet is blocked.
Set temperature is too high.

AIR CONDITIONER CYCLES ON AND OFF TOO MUCH OR DOES NOT COOL

The air conditioner is not properly sized for your room.
capabilities of your portable air conditioner. Portable air conditioners are
designed as supplemental cooling to local areas within a room.
The flter is dirty or is obstructed by debris.
There is excessive heat or moisture (open container cooking, showers, etc.)
in the room. Use a fan to exhaust heat or moisture from the room. Try not to use
heat-producing appliances during the hottest part of the day.
The louvers are blocked. Install the air conditioner in a location where the
louvers are free from curtains, blinds, furniture, etc.

DISPLAY ERROR CODE

If the unit displays error code E5, it is water full in the unit, you should drain the
water, see "Draining the air conditioner". After draining, you can operate and use
the unit again.
If the unit display error code E1/E2/E3/E4/EA, please contact customer service.
Use exhaust vent fans while cooking or
Clear air outlet.
Lower set temperature.
The use of more effcient
Lower set temperature. See
Clean the flter.
Check the cooling
Clean the flter.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

043-6128-0043-6130-2043-6131-0043-6129-8043-5499-2

Table of Contents