Software Updating; Rs-232C Method Description (Hyperterminal); Chapter 3. Adjustment; After Replacement Of Any Pwb And/Or Ic For Repair, Note The Following - Sharp LC-32D44E Service Manual

Hide thumbs Also See for LC-32D44E:
Table of Contents

Advertisement

LC32D44E-BK
CHAPTER 3.
ADJUSTMENT

[1] After replacement of any PWB and/or IC for repair, note the following.

When replacing the following units, be sure to prepare the new units loaded with updated software.
MAIN-UNIT:
DUNTKE449FM02
Note that an IC into which ROM data is written is available for MAIN-UNIT servicing (see below)
IC1902
RH-iXC448WJZZS
IC1922
RH-iXC447WJZZS
IC2321
RH-iXC206WJQZS
IC8101
RH-iXC639WJZZS

[2] SOFTWARE UPDATING

There are 2 methods to update software in the VCTp: I2C method, RS-232C HyperTerminal and RS-232C Tera Term method.
RS-232C method is allowed when the TV is working properly and the action should be only software upgrade.

1. RS-232C Method Description (HyperTerminal).

The hardware tools requirement are:
1. A Modem-null (Cross type) DB9 female to DB9 female cable.
2. Make the connections as indicated in the figure:
Before using RS-232C updating method is necessary to configure a Terminal PC software. HyperTerminal has been selected as a Terminal soft-
ware because it's include in all Windows versions as an accessory, and you can find it inside "Accessories\Communications" folder. For this rea-
son, please follow carefully the next steps:
1) First time HyperTerminal is used, it's necessary to configure some settings. Follows next action to configure two connection: low speed
(9600bps) and high speed (115200bps).
2) Create a New Connection file with name "P55_9600bps".
3) Select a free COM port and select the Port Settings properties as follows:
EDID (HDMI)
EDID (HDMI)
EDID (PC)
EEPROM
Computer
LC32D44E/S/RU-BK/GY (1st Eddition)
Service Manual
TV set
TV Set
RS-232C
IOIOI
3 – 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-32d44ru-bkLc-32d44sLc-32d44gy

Table of Contents