ELECTRONIC CLIMATE CONTROL

see Fig. 4
(CDE2ECC & CDE3ECC models only)
Operation
The electronic control allows MANUAL and AUTO
operation.
In MANUAL ON mode there are three heat settings:
L/H Side Heat, R/H Side Heat and High Heat
In AUTO mode the heater comes on as per the
programmed timer settings (see Setting programs). At any
point if the heater is active i.e. heat is being produced,
the ' ' neon is lit - see Fig. 4.
Initial Operation
When the heater is connected to the mains the ' ' neon
will be lit and the display is blank. Press the ' ' button
and the display goes to full heat set to 35
Note: All display characters are displayed in Fig. 13.

Standby Mode

With the heater ON if the ' ' button is pressed, the heater
will go into standby mode, heater switches off, the display
goes blank and only the MAINS ON neon ( ) remains
lit. On pressing the ' ' button again the heater will come
on in the mode and with the settings it had prior to going
into standby mode.
Setting Current Time
1. Press and hold ' ' and the clock symbol ' ' appears
on the top left hand side of the screen. The user can
now set the time.
2. The hour digit will now flash. To adjust the hour use the
' ' & ' ' buttons. Confirm the hour digit by pressing
'
'.
3. The minute digit will flash. To adjust the minute use the
' ' & ' ' buttons. Confirm the hour digit by pressing
'
'. The display will return to the state before
entering set time.
N.B. If no keys are pressed after 4 minutes the display
will revert to the state prior to entering set time.
Manual Operation
Pressing ' ' from the default HIGH screen (Fig. 8)
brings the heater into AUTO mode - see 'Setting the
Timer Programs'. Press again to put the heater into OFF
mode - see Fig. 6. Press again for left hand side heat (
appears on LCD display - see Fig. 7). Press again
for right hand side heat (
Press again brings the user full circle to FULL heat mode
(
appears on LCD display).
Setting the Desired Temperature
The desired temperature can be set using the ' ' or ' '
keys. The temperature can be set from 5
this will be shown on the display. When the temperature
is reached the heater will automatically switch OFF. If the
ambient temperature drops the heater will come on again
automatically. Note the electronic climate control device
conserves energy and assists with temperature regulation
e.g. if the heater is set to HIGH heat and the temperature
is set to 28
C, at 27
C the heater will switch to a lower heat
o
o
setting. Then at 28
C the heater will switch off
o
C - see Fig. 8.
o
appears on LCD display).
C to 35
C and
o
o
completely.
Setting the Timer Programs
Two program settings are possible, P1 and P2. Only high
heat is possible for program settings. Press ' ' once to set
the programs, starting with P1 AUTO ON – See Fig 10.
1. The hour digit will now flash. To adjust the hour use the
' ' & ' ' buttons. Confirm the hour digit by pressing
'
'.
2. The minute digit will now flash. To adjust the minute
use the ' ' & ' ' buttons. Confirm the hour digit by
pressing '
'.
3. Now P1 AUTO OFF is displayed, P1 off time can now
be set. Repeat steps 1 & 2 to set P1 off time.
At this point either:
(a) Press ' ' to exit the Program mode and return
to AUTO mode. The heater is now in AUTO mode.
The heater will
on programme P1 previously entered.
OR
(b) Repeat steps 1 - 3 as above to set the programme
for P2.
At this point press ENTER or PROG to exit the Programme
mode. The heater is now in AUTO mode. The heater will
switch ON and OFF depending on programme P1 & P2
previously entered. If after programming and returning to
the AUTO mode display, P1 or P2 is active, the display
will show PROG 1 AUTO ON or PROG 2 AUTO ON
depending on which is active - see Fig. 11. An OFF time
cannot be entered which is less than the corresponding
ON time. When setting the timer programs if no keys are
pressed, the display will (after 4 minutes) revert to the
previous display i.e. display prior to entering Program
mode.
Run Programs
If MODE is pressed until AUTO appears on the screen
(either AUTO-ON or AUTO-OFF), the heater will run both
P1 and P2 program as they are set.
NOTE: The heater cannot be programmed to run P1
only or P2 only.
To cancel P1, set P1 OFF time to be same as P1 ON time.
To cancel P2 set P2 OFF time to be same as P2 ON time.
Review Program settings
To review the program settings the heater must be in
AUTO mode. Press ENTER and the times for PROG 1
ON, PROG 1 OFF, PROG 2 ON and PROG 2 OFF will
be displayed consecutively for 2 seconds. The display will
automatically return to the state it was in before ENTER
was pressed.
FROST Protection Mode
With the heater in any mode, OFF, MANUAL ON or
AUTO, if the displayed set temperature is reduced to 5
the heater will go into FROST Protection mode - see Fig.
12. In this mode only, if the ambient temperature drops
below 5
C, will the heater come on. This is to prevent
o
freezing. In FROST Protection mode the heater comes
on in the high heat mode only. Pressing the ' ' button is
the only way to bring the heater out of this special mode.
switch ON and OFF depending