Overheat Cutoff Fuse - A.O. Smith 110 Indoor Service Manual

Direct vent on-demand water heater
Table of Contents

Advertisement

10-12. Overheat cutoff fuse

Unit Part #
Function
Failure events
Effects on the water
heater if the overheat
cutoff fuse fails
Error codes when the
overheat
cutoff
fuse
fails
Diagnostic
Color/Number of wires
Solder will melt at temperature exceeding 430
#413
AOS Part #
-The overheat cutoff fuse contains solder with a melting point of 430˚F
(221˚C).
-Detects excessive temperatures within the water heater, especially around
the heat
exchanger and
communication between the computer board and gas valves will sever,
shutting down the water heater instantly. The "11" or "12" error code will
display.
1. Unable to detect the excessively high temperatures within the water
heater.
1. Flames from burner may penetrate a ruptured/damaged heat exchanger.
2. Gas valves will not operate.
11
1. Visual inspection: connection/breakage of wires.
2. Check voltages and resistance: proper range of values shown below.
Blue-Blue
Less than 1.0 Ω
110 Indoor / 110 Outdoor Service Manual
319143-149
combustion
˚F(±9˚F) or 221˚C(±5˚C)
The O.H.C.F. has a red line on itself.
28
CONFIDENTIAL
Ver. 1.01
Checkpoint
chamber. Upon
detection,
12
C2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T-kjr2-inT-kjr2-os

Table of Contents