OPTIONAL BLOWER INSTALLATION INSTRUCTIONS

FBB6 for Unvented Gas Fireplace Models VFP24FP2 Series & VFP24FP3 Series
INSTALLING OPTIONAL BLOWER
1.
Remove bottom louver.
2.
Remove upper louver.
3.
Remove screen front by lifting upward on screen front.
4.
Remove rear log support from inner casing (three 10 x 1/2"
screws). See Figure 25.
5.
Remove burner assembly (four 10 x 1/2" screws). See Figure
26.
6.
Remove two 10 x 1/2" screws on the left side of the firebox
bottom. See Figure 27.
Page 32
Figure 25
Figure 26
Figure 27
7.
Insert blower assembly in left side of outer casing. Motor with
wiring will be to the inside of the outer casing, blower chute
will be facing upward. See Figure 28.
Figure 28
8.
Push blower assembly against the left wall of the outer casing.
The magnets installed on the bottom of the bracket will hold
it in place.
9.
Replace the two 10 x 1/2" screws on the left side of the firebox
bottom.
10. Attach two flag terminals on wire harness to fan control bracket.
11. Attach fan control bracket to top of inner casing with
10 x 1/2" screw. Refer to Figure 29 for correct position of fan
control bracket for 10,000 BTU/hr input or 20,000 BTU/hr input.
Figure 29
30411-0-0612