Preparation; Burner Removal - Stanley Alpha 120 Servicing Instructions

Twin burner, oil fired central heating range cooker
Table of Contents

Advertisement

Burner Removal

PREPARATION

WARNING: BEFORE REMOVING SERVICE ACCESS
COVERS OR THE OIL BURNERS ENSURE THAT ALL
ELECTRICAL SUPPLIES TO THE APPLIANCE HAVE
BEEN ISOLATED.
The burners can be removed without disconnecting the oil
supply pipe. However if the filters are being cleaned or a
pressure gauge fitted to the pump then the oil supply
should be turned OFF and arrangements made to catch
any oil which will leak from the oil pump.
BURNER ACCESS
SEE FIG. 1
1. Open up the bottom burner access door. Remove
door and put in a safe place.
2. Remove 2 inner panel securing screws and remove
panel.
FIG. 1
5
DESN 514813