Pump Overrun Facility; Overheat Safety Thermostats - Stanley Alpha 120 Servicing Instructions

Twin burner, oil fired central heating range cooker
Table of Contents

Advertisement

PUMP OVERRUN FACILITY

When the programmer switches OFF the boiler channel
then the water circulating pump will be switched off. If
during the period shortly after this the residual heat in the
appliance causes the water temperature in the boiler to
rise above 65°C then the pump overrun thermostat will
change over. This will switch on the circulating pump.

OVERHEAT SAFETY THERMOSTATS

BOILER
This thermostat is a safety cut-out device which is
intended to operate if the other controls fail. This control
will "lock-out" and switches everything off except for the
programmer clock and the "Pump Overrun" facility.
This thermostat has to be manually reset once the
temperature has cooled down.
COOKER
This thermostat is a safety cut-out device which operates
if the control thermostat fails.
This
thermostat
temperature has cooled down.
24
Electrical Controls
automatically
resets
once
the