Air Conditioner Operation In Thermistor Error - Sharp AY-X12PSR Service Manual

Split type room ac
Table of Contents

Advertisement

SHARP(CHINA)INVESTMENT CO.,LTD
Outdoor
unit
13
discharge
thermistor
open-circuit error
Outdoor unit outside
14
air
temperature
ther-mistor
short-circuit error
Discharge
pipe
15
temperature themister
short-circuit error
Discharge
pipe
16
temperature themister
open-circuit error
Serial signal error
17
Outdoor unit DC fan
18
error

[2] AIR CONDITIONER OPERATION IN THERMISTOR ERROR

1. Indoor unit
Item
Mode
Room tempe-
Auto
rature ther-
mistor (TH1)
Cooling
Dehumidifying
Heating
Heat exchanger
Cooling
thermistor (TH2)
Drying
Heating
2. Outdoor unit
Description
Indoor and outdoor unit stops
if there is short-circuit or
break in outdoor unit heat
exchanger thermistor
Indoor and outdoor unit stops
if there is short-circuit or
break in outdoor unit heat
exchanger thermistor
Indoor and outdoor unit stops
if there is short-circuit or
break in outdoor unit heat
exchanger thermistor
Indoor and outdoor unit stops
if there is short-circuit or
break in outdoor unit heat
exchanger thermistor
Indoor and outdoor unit stops
if outdoor unit cannot receive
serial signal from indoor unit
for 2minutes.
Operation stops if there is no
input of rotation pulse signal
from out-door unit fan motor
for 30 seconds
Control
When resistance is
operation
low (tempera-ture
judged higher than
actual)
Operation
mode
Cooling
judgment
activated even if room
temperature is low.
Frequency con-
Room becomes too cold
trol
Room temperature
Normal operation.
memory frequency
control
Frequency control
Room does not become
warm
Freeze prevention
Indoor unit evaporator
may freeze.
Cold air prevention
Cold
deactivates
and cold air discharges.
Detection
Reset condition
period
At
compressor
Operation OFF or ON
startup
At
compressor
Operation OFF or ON
startup
At
compressor
Operation OFF or ON
startup
At
compressor
Operation OFF or ON
startup
When
in
Reset after reception of
operation
serial signal
When
outdoor
Operation OFF or ON
unit
fan
is
in
operation
Short-circuit
mode
is
The unit stops
The unit stops
The unit stops
The unit stops
The unit stops
air
prevention
The unit stops
too
soon
3-2
Indoor unit
Indoor
Outdoor
error display
unit
E3
yes
E8
yes
E8
yes
E8
yes
E0
yes
EF
yes
When resistance
Open-circuit
is high (tempera-
ture judged lower
than actual)
Heating
mode
is
The unit stops
activated even if room
temperature is high.
Room
does
not
The unit stops
become cool.
Normal operation.
The unit stops
Room becomes too
The unit stops
warm.
Compressor
stops
The unit stops
occasionally.
Cold air prevention
The unit stops
deactivates too slow.
unit
yes
yes
yes
yes
yes
yes