Sizing The Electrical Service; Ground Fault Protection (Not Recommended) - Aquacal Heat Pump Installation Manual

Aquacal heat pump user manual
Table of Contents

Advertisement

Electrical Requirements (continued):
• All AquaCal heat pumps have two (2) identical data plates affixed: one can be found outside the
unit, on right front corner; the second data plate is located behind the front access panel, on the
electrical enclosure cover.
• Refer to either equipment data plate for unit-specific electrical power supply requirements.
• Based on data plate information, size wiring, wiring devices, and over-current protection per
applicable codes and standards.
• Refer to drawing below for data plate items specific to electrical installation requirements. On the
installed heater data plate, the areas depicted below, numbered 1-11, will contain the information
required to size the electrical service and over-current protection.
A Word Concerning Ground-Fault Protection
• The National Electrical Code (NEC) contains no standards requiring Ground-Fault Interruption
protection (via GFI Circuit Breaker or otherwise) of "Fixed" or "Stationary" equipment, under
article 680: Swimming Pools, Fountain, & Similar Installations, or Article 440: Air-Conditioning &
Refrigeration Equipment.
• The preceding standards govern the installation of AquaCal (and other manufacturers') heat
pumps. AquaCal heat pumps are designed, and safety tested by a certified laboratory, to be
installed under applicable standards detailed within the NEC.
• AquaCal does not recommend the use of ground fault protective devices in conjunction with heat
pumps. Service calls, found to be due to "nuisance" tripping of ground fault devices, are
not covered under the AquaCal factory warranty.
INSTALLATION

Sizing the Electrical Service...

Reference the Equipment Data Plate
ELECTRICAL PORTION of DATA PLATE
#6
#9
#1
#2
#7
#10
#4
#3
#5
#8
#11
45