6. Installation

6.1 Installation of Indoor, Outdoor unit
1) Selection of the best location
Indoor unit
• There should not be any heat source or steam near
the unit.
• There should not be any obstacles to prevent the
air circulation.
• A place where air circulation in the room will be
good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into con-
sideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the
wall, ceiling, fence, or other obstacles.
Outdoor unit
• If an awning is built over the unit to prevent direct
sunlight or rain exposure, be careful that heat radia-
tion from the condenser is not restricted.
• There should not be any animals or plants which
could be affected by discharged hot air.
• Ensure the space indicated by arrows from the wall,
ceiling, fence, or other obstacles.
Piping length and the elevation
PIPE SIZE
MODEL
GAS SIDE LIQUID SIDE
~100K
11/10"
(BTU/h)
~150K
1"
(BTU/h)
~200K
11/10"
(BTU/h)
Max.
Max.
Length
Elevation
A (m)
B (m)
1/2"
40
25
5/8"
40
25
5/8"
40
25
100cm
5cm
50cm
Indoor unit
– 20 –
40cm
150cm
50cm
A
Outdoor unit
B
5cm
50cm