Sanyo VPC-SH1BK Service Manual page 20

Dual camera with li-ion battery charger
Hide thumbs Also See for VPC-SH1BK:
Table of Contents

Advertisement

Dsc Calibration
AWB Results:
1:
WB=268,515,694
CHECK=128,129,125
WB_FS=267,512,690
CHECK_FS=128,129,121
IR_TEMP_AD=453
IRIS_PWM1=193,158
IRIS_PWM2=147,139
IRIS_PWM3=133,128
IRIS_PWM4=124,119
IRIS_PWM5=111
MS=2228,858
MS_M=1702,1149
MS_C=1024,956
MS_C2=945,940
MS_C3=938,936
Fno_FOR_ISO=-1
SS_FOR_ISO=-1
YLEVEL_FOR_ISO=-1
When all of the AWB adjustment screen
is not displayed, use a scroll bar.
Adjustment value determination is effectuated using the
"CHECK", "CHECK_FS", "MS", "MS_M", "MS_C", "MS_C2",
"MS_C3", "IR_TEMP_AD", "IRIS_PWM1", "IRIS_PWM2",
"IRIS_PWM3", "IRIS_PWM4" and "IRIS_PWM5" values. If
CHECK = wc0, wc1, wc2
CHECK_FS = wfc0, wfc1, wfc2
MS = ms1, ms2
MS_M = ms3, ms4
MS_C = ms5, ms6
MS_C2 = ms7, ms8
MS_C3 = ms9, ms10
IR_TEMP_AD = itad
IRIS_PWM1 = s1, s2
IRIS_PWM2 = s3, s4
IRIS_PWM3 = s5, s6
IRIS_PWM4 = s7, s8
IRIS_PWM5 = s9
the adjustment values fulfill the conditions below, they are
determined as within specifications.
Adjustment value determination
wc0=128 ± 2, wc1=128 ± 2, wc2<=130 ± 40
wfc0=128 ± 2, wfc1=128 ± 2, wfc2<=130 ± 40
1900<=ms1<=2600, 400<=ms2<=1000,
1400<=ms3<=1800, 900<=ms4<=1300,
700<=ms5<=1200, 600<=ms6<=1100,
600<=ms7<=1100, 600<=ms8<=1100,
600<=ms9<=1100, 600<=ms10<=1100,
270<=itad<=967
s1>s2>s3>s4>s5>s6>s7>s8>s9
Adjustment values other than the above are irrelevant.
x
OK
Copy
– 20 –
4. CMOS White Point Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select "CCD Defect" on the LCD "Test", and click the "Yes".
3. After the adjustment is completed, OK will display.
4. Click the OK.
5. CMOS Black Point And White Point Defect Detect
Adjustment In Lighted
Camera
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100 ± 20 (K)
Luminance: 900 ± 20 (cd/m
Adjusting method:
1. Set a distance of 0.5-1.0 cm between the pattern box and
the camera.
2. Double-click on the DscCalDi.exe.
3. Select "CCD Black" on the LCD "Test", and click the "Yes".
4. After the adjustment is completed, the number of defect
will appear.
5. Click the OK.
6. Gyro Sensor Zero Offset Adjustment
Preparation:
POWER switch: ON
Note:
Do not vibrate after turning on the camera.
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select "EIS Adj" on the LCD "Test".
3. After the adjustment is completed, the adjustment value
will appear.
Carry out the adjustment again if NG will display.
Pattern box
(color viewer)
2
)