Kohler COMMAND CH18-745 Service Manual page 161

Horizontal crankshaft
Hide thumbs Also See for COMMAND CH18-745:
Table of Contents

Advertisement

Section 9
Disassembly
Figure 9-28. Remove B+ Lead from Terminal Plug.
3. The rectifier-regulator does not have to be
detached from the blower housing. If the engine is
equipped with SMART-SPARK
should be removed from the cylinder baffle or
blower housing. See Figure 9-29. The module
willing hang loose as part of the wiring harness.
Figure 9-29. Removing the Spark Advance Module
(Applicable Models).
9.8
the SAM module
Figure 9-30. Note Location of Two Short Screws.
Figure 9-31. Removing Outer Baffles.
4. Remove the three (each side) hex. flange screws
securing the outer baffles. Note the location of
any lifting strap and position of the two short
screws (one each side on bottom) for reassembly.
See Figure 9-30.
5. Remove the outer baffles on both sides. See
Figure 9-31.
6. On engines equipped with a metal grass screen,
remove the screen before removing the blower
housing. See Figure 9-32. Plastic grass screens
can be removed after the blower housing is
removed.